Troubleshooting guide
4.1
Error Message
Code
Error
Description
Possible Cause
Corrective Action
section
E017
Temperature
sensor broken
or
disconnected.
The control
reads out of
range values.
Bad connection
Temperature sensor
broken.
Check the connectors and
the harness Replace the
sensor
7.14
E001
Temperature
sensor shorted.
Bad connection
Temperature sensor
broken.
Check the connectors and
the harness Replace the
sensor
7.14
E004
Electronic boards
over temperature
(t>100°c).
Overheating of
the internal
parts.
Cooling fan broken
Replace the cooling fan
7.2
Bad connections
between cooling fan
and electronics.
Check connections
--
Air flow through the
cooling channel is not
sufficient.
Check proper installation.
The slot between the
control panel and the door
must be free.
--
Defective cooling fan
relay on main power
board
Replace the power board.
7.18
Faulty NTC sensor on
main power board
Replace the power board.
7.18
E016
Oven cavity
overheating
Runaway
temperature
condition
during
cooking.
One or more relays are
stuck, driving heating
elements.
Check the contact of
Element relays
Replace the power board
7.18
E008
Latch
mechanism
time-out
overflow
The control
can’t perform
any locking or
unlocking cycle
within the
maximum
Latch mechanism
problem.
--
Latch motor problem
Replace the motor
7.8
Defective latch micro
switch
Replace the micro switch
7.9