© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
21
802725
Step 12: Check Heat Source
Electric Dryers
Close the loading door and start the dryer in a heat
setting (refer to the Dryer User’s Guide supplied with
the unit). After the dryer has operated for three
minutes, the exhaust air or exhaust pipe should be
warm.
Gas Dryers
IMPORTANT: This operation is to be conducted
by qualified personnel only.
To view the burner flame, remove the lower front
panel of the dryer.
Close the loading door, start the dryer in a heat setting
(refer to the Dryer User’s Guide supplied with the
unit). The dryer will start, the igniter will glow red and
the main burner will ignite.
IMPORTANT: If all air is not purged out of gas
line, gas igniter may go off before gas is ignited. If
this happens, after approximately two minutes
igniter will again attempt gas ignition.
IMPORTANT: If igniter does not light, make sure
gas is turned on.
After the dryer has operated for approximately five
minutes, observe burner flame through lower front
panel. Adjust the air shutter to obtain a soft, uniform
blue flame. (A lazy, yellow-tipped flame indicates lack
of air. A harsh, roaring, very blue flame indicates too
much air.) Adjust the air shutter as follows:
1. Loosen the air shutter lockscrew.
2. Turn the air shutter to the left to get a luminous
yellow-tipped flame, then turn it back slowly to
the right to obtain a steady, soft blue flame.
3. After the air shutter is adjusted for proper flame,
tighten the air shutter lockscrew securely.
4. Reinstall the lower front panel.
After the dryer has operated for approximately three
minutes, exhaust air or exhaust pipe should be warm.
For personal safety, lower front panel must
be in place during normal operation.
W046
WARNING
Any disassembly requiring the use of tools
must be performed by a suitably qualified
service person.
W299
WARNING
DRY212N
1
Shut-off Valve Handle
4
3.1 mm (1/8 in.) Pipe Plug
(For checking manifold pressure)
2
Air Shutter Lockscrew
3
Air Shutter
5
Open Position
6
Closed Position
Figure 20
1
2
3
4
5
6
Содержание LTKA6