© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
13
802725
Step 6: Position and Level the Unit
Position unit so it has sufficient clearance for
installation and servicing. Refer to
Figure 10
NOTE: Use of the dispenser drawer or unit doors
as a handle in the transportation of the unit may
cause damage to the dispenser or doors.
Place unit in position on a solid, sturdy and level floor.
Installing the unit on any type of carpeting, soft tile, a
platform or other weakly supported structures is not
recommended.
NOTE: Shaded areas indicate adjacent structure.
SWD795N
SWD7
9
5N
A
B
C
D
E
E
Dryer and Exhaust Duct Clearances
Area
Description
Minimum Clearance
A
Left Dryer Side
0 cm (0 in.)
B
Right Dryer Side
2.54 cm (1 in.)
C
Dryer Top
15.24 cm (6 in.)
D
Dryer Rear
10.2 cm (4 in.)
E
Exhaust Duct Clearance to Combustible Materials
5.1 cm (2 in.)
Содержание LTKA6
Страница 23: ......