Setup Menu: DN9340E
34
To set the IP Address manually
1
Turn the left control knob to highlight the area of the IP Address you wish to change.
2
Now turn the centre control knob to select a number from 0 to 255.
3
Press
HOME (SETUP)
to confirm the new IP Address.
Note
It is important that all units and the controlling PC have a unique IP
Address in order for the network to function correctly. For more
information on configuring your network, please see the HELIX DN9340E
and DN9344E RCS User Guide.
To change to DHCP mode
1
Step back through the Set
Up menus to the Ethernet IP
Network setup page and
rescan the network to check
the current IP Address.
2
Now turn the right control
knob to change the mode to
DHCP.
3
Press
HOME (SETUP)
to confirm
the mode change.
If you now step back through the Set Up menus and check the IP Address again, you will see the
address assigned by your DHCP server. In this mode, the IP Address is for display purposes only and
cannot be altered via the front panel.
Note
If network communication is not available, then the unit forces an IP
Address. You may then edit the IP manually as described above.
To change to Auto IP mode
1
Step back through the Set Up menus
to the Ethernet IP Network setup page
and rescan the network to check the
current IP Address.
2
Now turn the right control knob to
change the mode to Auto IP.
3
Press
HOME (SETUP)
to confirm the mode
change.
In Auto IP mode, when the unit is powered on it checks any other units within its daisy chained
network and automatically assigns a valid IP Address. The IP Address is displayed as read-only and
cannot be altered via the front panel.
Содержание HELIX DN9340E
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 10: ......
Страница 12: ......
Страница 22: ...Signal Flow DN9340E 12 5 SIGNAL FLOW DN9340E...
Страница 24: ...Operation DN9340E 14 6 1 3 Touchstrip Operation on the Home Page In the home page the touchstrip is inoperative...
Страница 59: ...Signal Flow DN9344 49 13 SIGNAL FLOW DN9344E...