Set Up Menu: DN9344E
50
14. O
PERATION
: DN9344E
The DN9344E is designed to be remotely controlled using one of the following methods:
•
Remote control from a master DN9340E unit. For details, see Section 9.
•
Remote control from a PC running the Elgar Library Manager and HELIX DN9344E RCS
add-in software. For details, see Section 10.
•
Relay operation – where DN9344E memories may be recalled using a simple contact
closure mechanism. For details, see Section 15.2.
15. S
ET
U
P
M
ENU
: DN9344E
15.1. General
The DN9344E provides various set up options for adapting the operation of the unit to best suit your
operational requirements and preferences, as follows:
•
Comms channel setting for remote control operation (Page 1)
•
Password Page (Page 2)
•
Analogue/Digital input source and clock reference options (Pages 3 and 4)
•
Digital output clock reference options (Pages 5 and 6)
•
Ethernet settings for remote control operation (Pages 7, 8 and 9)
These options are programmed in the Set Up menu and are described below in menu order.
To access the Set Up menu pages
At the Home page press and hold the
SET UP
button to open the menu.
Press the
SET UP
button repeatedly to step through the pages in turn.
Note that this menu does not ‘cycle’. On completing the set up, the menu returns to the Home page.
15.2. Remote Comms channels (Page 1)
The Comms page lets you select the communications channel on which the unit will send/receive data
to/from a controlling PC or master DN9340E unit. Note that each DN9344 has TWO independent
communications channels (one for Section 1 and one for Section 2) as it contains the equivalent of
TWO DN9340 master units.
Note that when using Ethernet communication, you will need to set up the unit’s IP address and
Subnet mask before selecting the comms channel, see Section 15.6 for further details.
In addition, this menu provides the option to enable the DN9344E for relay operation. This allows
memories to be recalled using a simple contact closure mechanism.
Содержание HELIX DN9340E
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 10: ......
Страница 12: ......
Страница 22: ...Signal Flow DN9340E 12 5 SIGNAL FLOW DN9340E...
Страница 24: ...Operation DN9340E 14 6 1 3 Touchstrip Operation on the Home Page In the home page the touchstrip is inoperative...
Страница 59: ...Signal Flow DN9344 49 13 SIGNAL FLOW DN9344E...