9.2.2
Setting a shorter tanning time
16
1
K4
K3
K2
Operating-hour meter
Toggle switch
Caution!
Only a qualified electrician may make the adjustment.
Disconnect the device from the mains.
If you prefer a
shorter tanning time
than 20 minutes (device setting
ex-works), please set the required time on the timer switch (K2/K4)
and on the safety timing relay (K3).
Adjust the K2/K4 timer switch to the required time (max. 20
minutes); then adjust the K3 safety timing relay to 110% of the time
set on the K2 timer switch (e.g. K2/K4 timer switch: 10 minutes,
K3 safety timing relay:11 minutes).
To have access to the K2 timer switch and the K3 safety timing
relay, move the device to a comfortable work position (see
Section 5.3.) and remove the cover plate (
16/1
).
Now the K2 timer switch and the K3 safety timing relay are
accessible.
Caution!
The maximum time set on the K2/K4 internal device
timer switch is 20 minutes.
The time set on the K3 internal safety timing relay must
not exceed 22 minutes.