SONNENWIESE
PAGE 27
5000511/11.19
10.
Technical data, wiring diagram, installation
plans
Technical data, dimensions and UV type*
Description
SONNENWIESE
Device type
7824
Power
(W)
2980
Mains connection
(V)
1N PE~50 Hz 230 V
Fuse
(A)
16 A
Weight
(kg)
65
Dimensions:
Length
(mm)
2000
Width
(mm)
490
Height
(mm)
230
Safety class
IP 22
Noise emission
≤
70 dB (A)
Ambient operating temperature
max. 35 °C
Humidity
≤
90% rel. humidity, non-condensating
*Subject to technical change.
Lamp assembly
UV type according to EN
60335-2-27
3 x BQ 1177 Z4 C
3
We recommend replacing the high-intensity lamp after approx. 750 operating hours.
Extract from the tanning table
Skin type II
Skin type III
Skin type IV
Maximum number of
sessions per year
60
(
¢
15 kJ/m
2
)
43
(
¢
15 kJ/m
2
)
33
(
¢
15 kJ/m
2
)
Lamp cover
In the device, the UV radiation sources are each covered with one XTT filter disk 322 interference (on
the user side) (product code number 02935) and one transparent filter disk 316 (on the burner side)
(product code number 02932).
A highly polished rolled reflector made from electropolished and anodized aluminium is found