Maintenance
5.4.
Maintenance of the high-intensity lamps
Caution!
Before starting maintenance or repair work, disconnect the device from the power supply.
Opening the dust cover
'
Opening/closing the dust cover, see Section 5.1.
The high-intensity lamps are equipped with a very specific
glass-filter configuration. The device must not be operated under
any circumstance if the filter disks are damaged or missing. The
inspection window (
5/1
) for the operating-hour meter is located
on the underside of the SONNENWIESE.
Risk of being burnt. Risk of inflammation of the eye caused by
ultra-violet radiation.
When immediately turning the high-intensity lamp back on again,
depending on type, it does not start instantly or does not reach full
power as it requires a cooling phase of approx. 4 minutes.
We recommend replacing the high-intensity lamp after approx.
750 operating hours.
When replacing the high-intensity lamp, please refer to the
equipment manufacturer or your specialized dealer. No liability
can be assumed if any other devices are fitted, other than the
original high-intensity lamps or ignition device.
5
1
Operating-hour meter
One XTT filter disk (mirrored) and one transparent filter disk is placed in front of each
high-intensity lamp.