SONNENWIESE
PAGE 19
5000511/11.19
9.
Specifications only for technicians and Klafs
professionals - Installing the equipment
Warning!
The device may only be installed by KLAFS professionals or authorized persons. Installing
the device requires at least two persons.
The installation areas must be well ventilated. Danger of overheating.
Warning!
All devices are intended exclusively for the tanning of persons inside buildings. Do not
operate the device within highly combustible areas or in drying rooms. The rooms must be
well ventilated.
Ensure there is a sufficient fresh-air supply in the tanning room. When determining the
installation location, the VDE regulations 0100 parts 701 (bathrooms) and 702 (pools,
swimming pools) must be considered. The equipment's protection class is IP X2 (drip-water
protection). In swimming pools, it may only be installed outside the safety zones; in
bathrooms, only within or beyond safety zone 3.
The assembly is mounted from inside the room in a cavity (suspended ceiling), is mounted
directly onto the ceiling, or is freely suspended, maintaining a distance to the ceiling.
With suspended or wire-mesh ceilings (Rabitz ceiling), the device is mounted with the
traction ropes onto the load-bearing ceiling and then moved using the traction ropes until it
flush against the suspended ceiling. Please contact an expert.
The SLM 8 N Fischer dowels and M8 x 85 eye bolts supplied for fixing the device are
suitable for use in concrete only. In the case of other ceiling material, please contact an
expert.
The wood-screw eye bolts supplied are only suitable for timber beams with a minimum
thickness of 80 mm.
The tanning device weighs approx. 65 kg; the dowel supplied can bear a load rating - in
the case of a B25 concrete ceiling - of up to approx. 3.5 kN (350 kg).
The ceiling must have an appropriate load-bearing capacity.
Ideally, the distance between the lounger surface and the SONNENWIESE should be 2
m. If there is a smaller or larger distance for construction reasons, please ensure that the
optimal tanning times are reduced or extended.
No flammable items may be located within the device's cone of light. The ceiling materials
must not be combustible. The housing temperature can reach up to 120 °C.
Make sure that items located near the device are UV-resistant; the manufacturer is not
liable for any damage which may result from such use.
Unblockingtool
Pressure spindle
Collar screw
Heavy
−
duty dowel
Clevis
Eye bolt
Snaphooks
Wood
−
screweye bolt
Plastic bag
Содержание 7824