67
EN
Technical specification / Connection
Cooking Zones
4
Supply Voltage
380-415V 3N ~ , 50Hz-60Hz
Installed Electric Power
7400 W
Product Size L×W×H(mm)
770x520x60
Building-in Dimensions A×B (mm)
750x495
Weight and Dimensions are approximate. Because we continually
strive to improve our products we may change specifications and de
-
signs without prior notice.
14. Connecting the hob to the mains power supply
•
If the cable is damaged or needs replacing, this should be done by
an after-sales technician using the proper tools, so as to avoid any
accidents.
•
If the appliance is being connected directly to the mains supply, an
omnipolar circuit breaker must be installed with a minimum gap of
3mm between the contacts.
•
The installer must ensure that the correct electrical connection has
been made and that it complies with safety regulations.
•
The cable must not be bent or compressed.
•
The cable must be checked regularly and only replaced by a pro
-
perly qualified person.
•
The installer must to use the H07RN-F power cord.
Please always check whether built-in
bridges
on the connection
ports have influence on your power concept.
The power supply should be connected in compliance with the rele-
vant standard, or a single-pole circuit breaker.
!
13. Technical specification