Table 3-14 Additional Speed Settings - Traversing
Traversing Speed
ft/min
Frequency – Hz
11
Factory Low Setting
10.0
12
11.0
13
11.9
14
12.8
15
13.7
16
14.6
17
15.6
18
16.5
19
17.4
20
18.3
25
22.9
30
27.4
35
32.0
40
36.6
45
41.1
50
45.7
55
50.3
60
54.9
66
Factory High Setting
60.0
3.11.6 All dual speed trolleys have a acceleration/deceleration time parameter range that can be
customized to a specific application. Refer to
Table 3-15
for specific trolley
acceleration/deceleration time ranges. To set custom acceleration/deceleration times for an
application, follow the procedure in
Table 3-16
.
3.11.7
Do NOT
set the deceleration/acceleration time to a value beyond the setting
range in
Table 3-15
.
Table 3-15 Trolley VFD Acceleration/Deceleration Time Parameter Ranges
Item
Parameter
No.
Product
Code
Default Value
Changeable Range for Setting Value
VFD
Value
(120Hz)
Acceleration
(sec)
VFD
(sec)
Trolley
(sec)
Acceleration
Time
C1-01
C1-03
C1-07
RY030
5.0
2.5
5.0 – 6.0
2.5 – 3.0
RY050
6.0
3.0
Unchangeable
Unchangeable
Deceleration
Time
C1-02
C1-04
C1-08
RY030
5.0
2.5
5.0 – 6.0
2.5 – 3.0
RY050
6.0
3.0
Unchangeable
Unchangeable
Содержание Harrington RY Series
Страница 15: ...15 2 3 Part Names Figure 2 1 RY Part Names...
Страница 42: ...42 Figure 3 20 Hoist Upper and Lower Limit Switch ULLS...
Страница 57: ...57 Table 5 8 Various shapes that require the wire rope to be replaced...
Страница 67: ...67 Table 6 9 Motor Brake Gap Capacity Code Brake Gap G inch mm RY030 RY050 0 032 0 8...
Страница 104: ...104 9 3 Trolley Frame Parts Figure 9 3 Trolley Frame Parts...
Страница 112: ...112 9 10 Hoist Motor Parts Figure 9 10 Hoist Motor Parts...
Страница 114: ...114 9 11 Trolley Motor Parts Figure 9 11 Trolley Motor Parts...
Страница 116: ...116 9 12 Control Panel Box Parts Figure 9 12 Control Panel Box Parts...
Страница 119: ...119 This Page Intentionally Left Blank...