Venting

requirements

Maximum length of 
vent system

Determine the length of 
vent system you need

WARNING — TO REDUCE THE
RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS,
OBSERVE THE  FOLLOWING:

Installation work and electrical
wiring must be done by qualified
person(s) in accordance with all
applicable Codes and Standards,
including Fire Rated Construction.
Sufficient air is needed for proper
combustion and exhausting of
gases through the flue (chimney)
of fuel burning equipment to
prevent back drafting. Follow the
heating equipment
manufacturer’s guideline and
safety standards such as those
published by the National Fire
Protection Association (NFPA),
and the American Society of
Heating Refrigeration and Air
Conditioning Engineers
(ASHRAE), and the local code
authorities.

When cutting or drilling into wall
or ceiling, do not damage
electrical wiring and other hidden
utilities.

Ducted fans must always be
vented to the outdoors.

WARNING — To reduce the risk of
fire, use only metal ductwork.

This unit must be grounded.

C.

The blower motor must be

connected to the downdraft vent
system wiring as described in the
downdraft vent system instructions for
connecting the exterior blower motor
wiring. Flexible armored or nonmetallic
cable must be used. A U.L./CSA-listed
strain relief must be provided at each
end of the power supply cable.

Wire sizes must conform to the
requirements of the National Electrical
Code ANSI/NFPA 70 — latest edition*
or Canadian Electrical Code, C22.1
and C22.2 No. 113-M1984 (or latest
edition),** and all local codes and
ordinances. 14 gauge wire (minimum)
is recommended.

Copies of standards listed may be 
obtained from:

* National Fire Protection Association

One Batterymarch Park
Quincy, Massachusetts 02269

** CSA International

8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575

90° elbow = 
5 ft. (1.5 m)

1 ft. round = 
1 ft. (0.3 m)

45° elbow = 
2.5 ft. (0.8 m)

Recommended standard 

10" (25.4 cm) fittings

Determine which venting method is best
for your application. Vent system can
extend either through the wall or the
roof.

Locate the exterior blower so that the
length of the vent system and the
number of elbows is kept to a minimum
to provide efficient performance. Where
possible, exterior blower should be
centered between wall studs or roof
rafters. The size of the vent system
should be uniform. Do not install two
elbows together. Use duct tape to seal
all joints in the vent system. Use
caulking to seal exterior wall or floor
opening around the cap.

Flexible vent is not recommended. It
creates back pressure/air turbulence
and greatly reduces performance.

Make sure there is proper clearance
within the wall or floor for exhaust vent
before making cutouts. Avoid pipes,
wires, or other vent systems that may
be running through the wall. Do not cut
a joist or stud unless absolutely
necessary. If a joist or stud must be cut,
then a supporting frame must be
constructed.

The exterior blower carton contains a
black plastic vent collar and a vent collar
plate.

• The black plastic vent collar attaches

to the exterior blower using four
screws provided. The 10" (25.4 cm)
round vent system attaches to this
collar.

• The vent collar plate attaches to the

front of the downdraft vent system
plenum so that the 10" (25.4 cm)
round vent can be attached to the
downdraft vent system.

Make sure that there is enough space
for any vent transitions that may be
needed between the exterior blower and
the connecting vent system.

For optimum performance, locate any
necessary vent transitions nearest to
the rangehood or downdraft that will be
used with this power system.

This exterior blower requires a separate
U.L./CSA approved wiring cable that
should be installed at the same time the
vent system is being installed.

Vent

Length

10" (25.4 cm) round   55 ft. (16.8 m)

Vent length is given as a general
reference only. For a longer vent run, or
smaller vent system, contact a qualified
and trained vent installer. Check with local
codes for makeup air requirements, if any.

It is recommended that you use round
vent instead of rectangular vent,
especially if elbows are required. If
rectangular vent is required, if should be
transitioned to 10" (25.4 cm) round vent
as soon as possible.

For best performance, use no more
than three 90° elbows. If more than one
elbow is used, make sure that there is
a minimum of 24 inches (61 cm) of
straight vent between any two elbows.
Do not install two elbows together.

To calculate the length of system you
need, add the equivalent feet (meters)
from chart below for each vent piece
that will be needed.

Page 2

install this side of the fan facing
an unoccupied space.

Содержание KPED892K

Страница 1: ... ordinances Important Observe all governing codes and ordinances It is the customer s responsibility To contact a qualified electrical installer To assure that the electrical installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA Standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinan...

Страница 2: ...e exterior blower should be centered between wall studs or roof rafters The size of the vent system should be uniform Do not install two elbows together Use duct tape to seal all joints in the vent system Use caulking to seal exterior wall or floor opening around the cap Flexible vent is not recommended It creates back pressure air turbulence and greatly reduces performance Make sure there is prop...

Страница 3: ... the 11 27 9 cm diameter hole making sure that the 1 1 4 or 3 0 cm diameter electrical wiring hole lines up with the hole in the wiring box 9 Attach the exterior blower to wall using screws appropriate for your installation All four holes in the back panel must be filled to prevent moisture that may get inside the exterior blower housing from leaking into the home 10 Seal all around the mounting s...

Страница 4: ...that may get inside the remote blower housing from leaking into the home 9 Seal all the shingles around the exterior blower housing flashing sheet and mounting screw heads or frame with Electrical Shock Hazard Disconnect power before making electrical connections Connect the ground wire to green ground screw in wiring box Failure to do so can result in death or electrical shock WARNING 1 Remove th...

Страница 5: ...Aid E Repairs to parts or systems resulting from unauthorized modifications made to the appliance F Replacement parts or repair labor costs for units operating outside the United States or Canada G In Canada travel or transportation expenses for customers who reside in remote areas KITCHENAID AND KITCHENAID CANADA DO NOT ASSUME ANY RESPONSIBILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES Some states...

Страница 6: ... impaired limited vision etc Referrals to local dealers service companies and repair parts distributors KitchenAid designated service technicians are trained to fulfill the product warranty and provide after warranty service anywhere in the United States To locate the designated KitchenAid service company in your area you can also look in your telephone directoryYellow Pages 1 If you need assistan...

Страница 7: ... permet on recommande qu un électricien qualifié vérifie que la liaison à la terre est adéquate Ne pas utiliser une tuyauterie de gaz pour la liaison à la terre En cas d incertitude quant à la qualité de la liaison à la terre de la hotte consulter un électricien qualifié Ne pas installer un fusible en série avec le conducteur neutre ou le conducteur de liaison à la terre IMPORTANT Avant d entrepre...

Страница 8: ...d aspiration vers le bas pour qu il soit possible d y raccorder le conduit rond de 25 4 cm 10 po Veiller à ce qu il y ait un espace disponible suffisant pour tout raccord de transition qu il serait nécessaire d installer entre le ventilateur extérieur et le système de raccordement Pour optimiser la performance placer tout raccord de transition nécessaire aussi près que possible de la hotte ou du s...

Страница 9: ...collerette du ventilateur extérieur sur l ouverture de dia 27 9 cm 11 po veiller à ce que le trou de 3 cm 1 1 4 po pour le passage du câble électrique soit aligné avec le trou de passage dans la boîte de raccordement du câblage 9 Fixer le ventilateur extérieur sur le mur avec des vis de taille appropriée Obturer les quatre trous du panneau arrière pour éviter l introduction d humidité dans la rési...

Страница 10: ...pour assurer l étanchéité entre les bardeaux et le ventilateur tout autour de la caisse du ventilateur au niveau du solin et sur les têtes de vis au niveau de la structure de support Risque de choc électrique Interrompre l alimentation électrique avant d effectuer des raccordements Connecter le conducteur de liaison à la terre avec la vis verte dans la boîte de connexion Le non respect de ces inst...

Страница 11: ...n autorisées effectuées sur l appareil F Coût de pièces de rechange ou de main d œuvre de réparation pour des appareils utilisés en dehors des États Unis ou du Canada G Au Canada frais de déplacement ou de transport pour les clients qui résident dans des régions éloignées KITCHENAID ET KITCHENAID CANADA NE SONT PAS RESPONSABLES POUR LES DOMMAGES FORTUITS OU INDIRECTS Certains États ou certaines pr...

Страница 12: ...les sont fabriquées selon les mêmes spécifications précises utilisées pour construire chaque nouvel appareil KitchenAid Pour localiser des pièces autorisées par l usine dans votre région téléphonez à notre Centre d interaction avec la clientèle votre Centre de service autorisé le plus proche ou le service de l usine KitchenAid en composant le 1 800 442 1111 Pour plus d assistance Si vous avez beso...

Отзывы: