Model KPED892K Exterior Blower

Installation Instructions and Use and Care Guide

Your safety and the safety of

others are very important.

We have provided many important safety
messages in this manual and on your
appliance. Always read and obey all safety
messages.

This is the safety alert symbol. 
This symbol alerts you to
potential hazards that can kill

or hurt you and others. 
All safety messages will follow the safety
alert symbol and either the word
“DANGER” or “WARNING”. These 
words mean:

All safety messages will tell you what the
potential hazard is, tell you how to reduce
the chance of injury, and tell you what can
happen if the instructions are not followed.

You can be killed or seriously injured if
you don’t immediately follow instructions.

You can be killed or seriously injured if
you don’t follow instructions.

WARNING

Before you start...

Electrical

requirements

DANGER

IMPORTANT:

READ AND SAVE THESE INSTRUCTIONS.

The installer must leave these instructions with the homeowner. The homeowner must keep these instructions for future
reference and for local electrical inspectors use.

Proper installation is your responsibility.
Make sure you have everything
necessary for correct installation. It is
the responsibility of the installer to
comply with the clearances specified.

To avoid damage to motor bearings
and impellers, keep drywall spray,
construction dust, etc. away from the
exterior blower.

Important: Observe all governing
codes and ordinances.

Important: Observe all governing
codes and ordinances.

It is the customer’s responsibility:

• To contact a qualified electrical

installer.

• To assure that the electrical installation

is adequate and in conformance with
National Electrical Code, ANSI/NFPA
70 — latest edition*, or CSA
Standards C22.1-94, Canadian
Electrical Code, Part 1 and C22.2
No.0-M91 - latest edition** and all local
codes and ordinances.

If codes permit and a separate ground
wire is used, it is recommended that a
qualified electrician determine that the
ground path is adequate.

Do not ground to a gas pipe.

Check with a qualified electrician if
you are not sure exterior blower is
properly grounded.

Do not have a fuse in the neutral or
ground circuit.

IMPORTANT

Before installing exterior mounted
blower, read the installation instructions
for the Kitchen downdraft system of
range hood that will be used in
conjunction with this power system.

The exterior blower is factory set at 
900 cfm (424.7 l/s).

This fan is suitable for use with solid-
state speed controls.

A.

A 120-volt, 60-Hz, AC-only supply

wired for 15 amp service is required.

B.

The blower motor must be

connected with copper wire only.

Copies of standards listed may be 
obtained from:

* National Fire Protection Association

One Batterymarch Park
Quincy, Massachusetts 02269

** CSA International

8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575

Page 1

Care of your
exterior blower

Disconnect power supply and lock out
service panel before cleaning or
servicing.

To clean, remove cover and vacuum
blower and housing, being careful not
to damage blower wheel.

The motor is permanently lubricated.
Do not oil or disassemble.

Содержание KPED892K

Страница 1: ... ordinances Important Observe all governing codes and ordinances It is the customer s responsibility To contact a qualified electrical installer To assure that the electrical installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA Standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinan...

Страница 2: ...e exterior blower should be centered between wall studs or roof rafters The size of the vent system should be uniform Do not install two elbows together Use duct tape to seal all joints in the vent system Use caulking to seal exterior wall or floor opening around the cap Flexible vent is not recommended It creates back pressure air turbulence and greatly reduces performance Make sure there is prop...

Страница 3: ... the 11 27 9 cm diameter hole making sure that the 1 1 4 or 3 0 cm diameter electrical wiring hole lines up with the hole in the wiring box 9 Attach the exterior blower to wall using screws appropriate for your installation All four holes in the back panel must be filled to prevent moisture that may get inside the exterior blower housing from leaking into the home 10 Seal all around the mounting s...

Страница 4: ...that may get inside the remote blower housing from leaking into the home 9 Seal all the shingles around the exterior blower housing flashing sheet and mounting screw heads or frame with Electrical Shock Hazard Disconnect power before making electrical connections Connect the ground wire to green ground screw in wiring box Failure to do so can result in death or electrical shock WARNING 1 Remove th...

Страница 5: ...Aid E Repairs to parts or systems resulting from unauthorized modifications made to the appliance F Replacement parts or repair labor costs for units operating outside the United States or Canada G In Canada travel or transportation expenses for customers who reside in remote areas KITCHENAID AND KITCHENAID CANADA DO NOT ASSUME ANY RESPONSIBILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES Some states...

Страница 6: ... impaired limited vision etc Referrals to local dealers service companies and repair parts distributors KitchenAid designated service technicians are trained to fulfill the product warranty and provide after warranty service anywhere in the United States To locate the designated KitchenAid service company in your area you can also look in your telephone directoryYellow Pages 1 If you need assistan...

Страница 7: ... permet on recommande qu un électricien qualifié vérifie que la liaison à la terre est adéquate Ne pas utiliser une tuyauterie de gaz pour la liaison à la terre En cas d incertitude quant à la qualité de la liaison à la terre de la hotte consulter un électricien qualifié Ne pas installer un fusible en série avec le conducteur neutre ou le conducteur de liaison à la terre IMPORTANT Avant d entrepre...

Страница 8: ...d aspiration vers le bas pour qu il soit possible d y raccorder le conduit rond de 25 4 cm 10 po Veiller à ce qu il y ait un espace disponible suffisant pour tout raccord de transition qu il serait nécessaire d installer entre le ventilateur extérieur et le système de raccordement Pour optimiser la performance placer tout raccord de transition nécessaire aussi près que possible de la hotte ou du s...

Страница 9: ...collerette du ventilateur extérieur sur l ouverture de dia 27 9 cm 11 po veiller à ce que le trou de 3 cm 1 1 4 po pour le passage du câble électrique soit aligné avec le trou de passage dans la boîte de raccordement du câblage 9 Fixer le ventilateur extérieur sur le mur avec des vis de taille appropriée Obturer les quatre trous du panneau arrière pour éviter l introduction d humidité dans la rési...

Страница 10: ...pour assurer l étanchéité entre les bardeaux et le ventilateur tout autour de la caisse du ventilateur au niveau du solin et sur les têtes de vis au niveau de la structure de support Risque de choc électrique Interrompre l alimentation électrique avant d effectuer des raccordements Connecter le conducteur de liaison à la terre avec la vis verte dans la boîte de connexion Le non respect de ces inst...

Страница 11: ...n autorisées effectuées sur l appareil F Coût de pièces de rechange ou de main d œuvre de réparation pour des appareils utilisés en dehors des États Unis ou du Canada G Au Canada frais de déplacement ou de transport pour les clients qui résident dans des régions éloignées KITCHENAID ET KITCHENAID CANADA NE SONT PAS RESPONSABLES POUR LES DOMMAGES FORTUITS OU INDIRECTS Certains États ou certaines pr...

Страница 12: ...les sont fabriquées selon les mêmes spécifications précises utilisées pour construire chaque nouvel appareil KitchenAid Pour localiser des pièces autorisées par l usine dans votre région téléphonez à notre Centre d interaction avec la clientèle votre Centre de service autorisé le plus proche ou le service de l usine KitchenAid en composant le 1 800 442 1111 Pour plus d assistance Si vous avez beso...

Отзывы: