5-5
HEATING ELEMENT &
TEMPERATURE SENSOR
Refer to page 4-16 for the procedure for servic-
ing the heating element & temperature sensor.
1.
Unplug washer or disconnect power.
2.
Disconnect the wire connectors from the
heating element and temperature sensor
terminals.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter test leads to the two
heating element terminals. The meter
should indicate between 10 and 20
Ω
.
5.
Disconnect the heating element tempera-
ture sensor connector from the CCU.
6.
Touch the ohmmeter test leads to the two
temperature sensor connector terminals.
The meter should indicate as shown in the
following chart.
Heating
Element
Temperature
Sensor Connector
HEATING ELEMENT RELAY
Refer to page 4-17 for the procedure for servic-
ing the heating element relay.
1.
Unplug washer or disconnect power.
2.
Disconnect the heating element relay con-
nector from the CCU.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter test leads to the two
relay connector pins. The meter should
indicate 15
Ω
.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
Temperature
Results
32
°
F (0
°
C)
35.9K
Ω
86
°
F (30
°
C)
9.7K
Ω
104
°
F (40
°
C )
6.6K
Ω
122
°
F (50
°
C)
4.6K
Ω
140
°
F (60
°
C)
3.2K
Ω
158
°
F (70
°
C)
2.3K
Ω
203
°
F (95
°
C)
1K
Ω
2 1
2 1
(Connector viewed From Wire End)
Содержание KHWS01PMT / WH
Страница 1: ...TECHNICAL EDUCATION JOB AID 4317352 KAL 4 FRONT LOADING AUTOMATIC WASHER MODEL KHWS01PMT WH ...
Страница 18: ...2 10 NOTES ...
Страница 30: ...3 12 NOTES ...
Страница 60: ...4 30 NOTES ...
Страница 80: ...6 14 NOTES ...
Страница 81: ...7 1 WIRING DIAGRAM ...
Страница 82: ...7 2 NOTES ...
Страница 84: ...8 2 NOTES ...
Страница 86: ......