5-2
DETERGENT DISPENSER
MOTOR & SWITCH
Refer to page 4-8 for the procedure for servic-
ing the degergent dispenser motor.
1.
Unplug washer or disconnect power.
2.
Disconnect the detergent dispenser mo-
tor and switch connector from the CCU.
3.
Set the ohmmeter to the R x 100 scale.
4.
Touch the ohmmeter test leads to the
indicated wire connector terminals. The
meter should indicate as follows:
Dispenser motor at pins 1 and 3 = 1400
to 1600
Ω
.
Dispenser switch at pins 5 and 6 = 0
Ω
.
Refer to page 4-10 for the procedure for servic-
ing the inlet valves.
1.
Unplug washer or disconnect power.
2.
Disconnect the inlet valve solenoid con-
nector from the CCU.
3.
Set the ohmmeter to the R x 100 scale.
4.
Touch the ohmmeter test leads to the
indicated wire connector terminals. The
meter should indicate between 750 and
850
Ω
.
INLET VALVE SOLENOIDS
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
HOT COLD
7 5 3 1
65 3 1
(Connector viewed From Wire End)
(Connector viewed From Wire End)