4-18
REMOVING THE DRAIN PUMP ASSEMBLY
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
WARNING
1.
Unplug washer or disconnect power.
2.
Turn off the water supply to the washer.
3.
Remove the three T-20 hex-head torx
screws from the toe panel and remove the
panel.
Drain Pump Assembly
4.
Raise the drain pump wiring cover and
disconnect the wire connector.
5.
Loosen the clamps, and disconnect the
drain and tub hoses from the drain pump.
6.
Remove the T-20 torx screw from the
drain pump.
7.
Slide the drain pump forward in its mount-
ing slots and lift it out of the washer. Do not
remove the rubber washers from the slots.
Pump Wire Connector
Wiring Cover
Tub Hose
Drain Hose
Torx Screw
Mounting Slot
Toe Panel
Screws