5-5
DRIVE MOTOR & CAPACITOR
Refer to page 4-12 for the procedure for ac-
cessing the drive motor and capacitor.
1. Unplug dryer or disconnect power.
2. Turn off gas supply to dryer.
IMPORTANT:
Discharge the capacitor by
touching a 20,000
Ω
resistor to the terminals
and chassis ground.
3. Disconnect the plug from the motor con-
nector and the wires from the capacitor.
4.
To test the motor capacitor:
a) Set the ohmmeter to the R X 10K scale.
b) Touch the ohmmeter test leads to the two
capacitor terminals. The meter should
indicate a low resistance, and then gradu-
ally increase towards infinity.
5.
To test the drive motor:
a) Set the ohmmeter to the R X 1 scale.
b) Touch the ohmmeter test leads to mo-
tor plug pins 6 (white) and 7 (blue). The
meter should read approximately 4
Ω
.
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
WARNING
1
3
5
7
2
4
6
8
Motor
Capacitor
Wires
Motor Plug
Содержание KHEV01RSS - Pro Line Plus Electric Dryer