4-11
e)
To remove the coils
from the burner
assembly, remove the two screws from
the bracket, and lift the two coils off the
cores.
Coils
5. Remove the two T-20 screws from the
burner funnel, and pull the funnel forward
so you can access the components.
Bracket Screws
6.
To remove the flame sensor:
a) Remove the blue and white wires from
the sensor terminals.
b) Remove the hex-head screw from the
flame sensor and remove the sensor
from the burner funnel.
7.
To remove the thermal cutoff (TCO):
a) Disconnect the two connectors with the
black wires from the TCO terminals.
b) Remove the hex-head screw from the
TCO bracket and remove the cutoff.
8.
To remove the high limit thermostat:
a) Disconnect the two connectors with the
white wires from the high limit thermo-
stat.
b) Remove the two hex-head screws from
the high limit thermostat and remove the
thermostat.
Burner Funnel Screws
Flame Sensor
TCO
High Limit
Thermostat
Screw
Blue & White
Screw
Screw
(1 of 2)
2 White
2 Black