4-26
REMOVING A SIDE PANEL
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1. Unplug dryer or disconnect power.
2. Turn off gas supply to dryer.
3. Remove the belt and drum from the dryer
(see pages 4-19 through 4-21 for the pro-
cedure).
4. Remove the left and right console screws
and capture nuts.
Front Panel
Screw & Capture Nut
5. Open the three wire retainers (see the photo
to the left) and remove the AC wiring.
6. Disconnect the drive motor connector from
the main harness plug.
7. Remove the blower motor assembly from the
dryer (see page 4-16 for the procedure).
3 Wire Retainers
& AC Wiring
8.
Electric Models:
Disconnect the following
connectors from the heater assembly:
a) Terminal Block (RD & BK wires)
b) Thermal Cutoff (TCO) (RD wire)
c) High Limit Thermostat (RD wire)
Blower Motor Assembly
Drive Motor Connector
Red
Electric Heater
Assembly
Terminal
Block
TCO
High Limit
Thermostat
Red
Red
Black
Содержание KHEV01RSS - Pro Line Plus Electric Dryer