6-29
6. Remove all the wire connections to the
machine control board. See Figure 11
below.
7. Remove screws that fasten the control
board to the mounting bracket, and pull it
from the mounting bracket.
ACCESSING & REMOVING THE
BLOWER ASSEMBLY
The blower assembly includes the tempera-
ture sensor, exhaust high limit, lint drawer
switch, and blower motor. See Figure 12.
NOTE: J connectors shown on the machine control electronics correspond with P connectors on the wiring diagram.
Figure 11.
Machine Control Electronics
Figure 12.
Blower motor components
ACCESSING THE BLOWER
ASSEMBLY COMPONENTS
1. Unplug dryer or disconnect power.
2. Turn off gas supply to dryer.
3. Remove the back panel and the duct
support bracket from the dryer.
4. Remove the toe panel from the dryer front.
5. Remove the 2 blower motor housing
screws from the dryer front.
6.
To remove the temperature sensor:
a) Pull the blower motor housing assem-
bly far enough forward so you can ac-
cess the temperature sensor.
b) Disconnect the two red-silver wires
from the exhaust high limit manual re-
set terminals. See Figure 13.
Temperature
Sensor Connector
Harness Connector
Temperature Sensor
Blower Motor Top Temperature
Sensor Clip
Housing Cover
Exhaust High
Limit Wires
Figure 13.
Temperature sensor connections