2
Tighten the bolts securely when mounting the unit on the machine table.
Please refer to the chart below for the
recommended tightening torque of the bolts.
Hex. Bolt Size
Torque N
・
m
M10 33.8
M12 58.9
M16 146.3
M20 294.3
Make sure the working area is clear of any foreign object and/or hand when the
unit is in operation to avoid any serious accident and/or injury.
Do not apply cutting force which exceeds the specification in this manual. Failure
to do so may cause severe injury and/or damage to the unit.
WARNING