![Kitagawa MR250RAE13 Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/kitagawa/mr250rae13/mr250rae13_instruction-manual_1972455025.webp)
19
NOTICE
NOTICE
9. Maintenance Work
9-1. Corrective Action in Case of Failure, and Disassembly
See the “Troubleshooting” if a failure occurred in the unit due to any reason. Also, for the
disassembly procedure when performing the maintenance work, refer to the parts list and
the procedure given in the corresponding maintenance item.
9-2. Before Performing Maintenance Work
When performing the maintenance work, shut off the power (primary power supply) of the
machining center or Kitagawa’s own controller to set the pressure adjusting valve of air
combination that supplies the air to the NC rotary table to 0 MPa or shut off the power of the
air compressor to exhaust the compressed air, so as to stop the supply of the working fluid.
Perform the maintenance work with the workpiece
removed. Performing the work with the workpiece left on
the table may cause the workpiece to be dropped out,
resulting in injuries.
Appropriate value in each maintenance item has been set
for smooth function of each device, and thus you should
observe it. Performing the maintenance work without
observing the appropriate value may cause NC rotary table
to fail or each device to be damaged.
Clamp the table clamp device of NC rotary table when
removing the workpiece.
CAUTION