29
13. Troubleshooting
Check corresponding item given in this chapter to take corrective actions when the unit
seems to be faulty. If the fault persists, please contact your sales agent (M/C maker) or us.
When making an inquiry, let us know the product type and manufacturing number marked
on the nameplate of the NC rotary table body.
Nameplate
Symptom
①:
Table does not rotate
Possible causes
Corrective actions
No cable connection between NC
rotary table and control unit
Check the cable for connection, and
connect it
Broken cable between NC rotary table
and control unit
Check the cable for continuity, and replace
it
Faulty clamp device
See “Symptom
⑤
”
Decentered workpiece, overloaded
fixture, and friction torque of steady
rest and rotary joint make the load
torque larger than the motor torque
Compare the specification of NC rotary
table with the work condition to make
improvement
Use of unit out of specified
temperature range
Adjust ambient temperature within
specified temperature range