![Kitagawa MR250RAE13 Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/kitagawa/mr250rae13/mr250rae13_instruction-manual_1972455045.webp)
39
NOTICE
17. Indexing Accuracy and Pitch Error
“
What is the linear length at the table circumference with
20 seconds cumulative indexing accuracy ?
”
“
What is the angle with a cumulative pitch error of
0.01mm ?
”
To answer these questions, use the following formula
representing the relationship between the angle and linear
length at the table circumference.
D
:
Diameter of Workpiece (mm)
α:
Angle (seconds)
L
:
Linear length at the table circumference (mm)
(1)
"
60
'
60
360
・・・・・・・・・・
・・・・・・・・・・
・・・・・・・・・・
・・・・・・・・・
×
×
°
=
×
α
π
D
L
(2)
10
125
.
4
60
60
360
5
・・・・・・・・
・・・・・・・・・・
・・・・・・・・・
D
L
D
L
×
×
=
×
×
×
×
=
π
α
(3)
10
424
.
2
60
60
360
6
・・・・・・・
・・・・・・・・・・
・・・・・・・・・
D
D
L
×
×
×
=
×
×
×
×
=
−
α
π
α
(Examples)
Assuming the diameter of the workpiece is 100mm, and by using formula (2), the
cumulative indexing accuracy of 20 seconds as linear length at table circumference will be
:
mm
L
004848
.
0
10
100
20
424
.
2
6
=
×
×
×
=
−
Therefore, the length is approximately 0.0048mm.
And converting the cumulative pitch error of 0.01mm to an angle, use formula (3)
:
"
25
.
41
100
10
01
.
0
125
.
4
5
=
×
×
=
α
Therefore, the angle is approximately 41 seconds.
Thus, by using the formula (2) and (3), the indexing precision and pitch error can be
converted in terms of linear length and angle.