14
・
Antirust oil is highly volatile and thus likely to catch fire, and also it mixes with air to
form explosive mixture gas.
・
The flash point of antirust oil applied to the unit at the delivery is 38
°
C. It may be
different from that of the antirust oil prepared by the customer.
4-5-4. Disposal of lubricating oil and hydraulic oil
Dispose of used lubricating oil and hydraulic oil exhausted from this unit in accordance with
the laws and regulations of your country. You may suffer punishment if you disposed of
waste oil without following the laws and regulations.
5. Inspection
Daily inspection
1) Confirm that the NC rotary tables (including jigs, if attached) are securely fixed.
2) Confirm that the chips accumulating in a rotary part of NC rotary table are removed.
3) Confirm that the electric connection cables and hoses are not damaged and the
pneumatic pressure is appropriate.
4) Confirm that the machine-zero operation and indexing operation and position.
5) Confirm that there is no abnormal vibration or noise. (eq. Body and motor)
6) Confirm that there is no abnormal heating. (eq. Body and motor)
Periodic inspection
(
Inspect the following items every six months.
)
1) Confirm that muddiness of the lubricating oil.
2) Confirm that the connectors are securely attached and there is no damage on the
cables.
3) Confirm that corrosion and breaking of the wiring in the motor case.
6. Use of NC Rotary Table
This unit is installed on the machining centers, and on its table surface the chuck or fixture
is attached to clamp the workpiece. It indexes the angle of machining position by the
control of machining center or Kitagawa’s own controller. During the machining, the
working fluid is supplied to retain the workpiece.