h AC Output Socket and
○
i AC Output Thermal Breaker:
A single AC Output socket is provided for direct AC output from the unit. An over-current
protective device (thermal breaker) is connected in series with the AC Output Socket to avoid over
current being withdraw from the AC Output socket.
Model
AC Output Socket Type
AC Output Thermal Breaker
120VAC series
NEMA 5-20 GFCI
20A
230VAC series
EU: Schuko-CEE 7/4)
16A
UK: British- BS1363
13A
AU: Australia-NS/NZS3112
10A
Model
By-Pass Mode Current (Maximum)
Inverter Mode Current (Maximum)
Total AC
Output
AC Output
Hardwire
AC Output
Socket
Total AC
Output
AC Output
Hardwire
AC Output
Socket
2000W/120VAC
30A
30A
20A*
16.7A
16.7A
16.7A
3000W/120VAC
30A
30A
20A*
25A
25A
20A *
2000W/230VAC
16A
16A
EU: 16A*
UK: 13A*
AU: 10A*
8.7A
8.7A
EU: 8.7A**
UK: 8.7A**
AU: 8.7A**
3000W/230VAC
16A
16A
EU: 16A*
UK: 13A*
AU: 10A*
13A
13A
EU: 13A**
UK: 13A**
AU: 10A*
* Limited by AC Output Thermal Breaker connected in series with the AC Output Socket.
** Limited by Inverter maximum AC Output Current during inverter mode.
○
j Display Port
The port is used to connect to the Multi-Function Display of the unit.
○
k Multi-Function Display
The display is used to provide unit information and for setting and programming the unit.
○
l BTS Port
The port is used for connecting to the optional Battery Temperature Sensor. The thermistor
installed inside the ring terminal is used to measure the battery terminal temperature and the unit
will make compensation on battery charging voltage for battery charging.
○
m Ignition Start Port
The port is used for connecting to the ignition start signal from vehicles to control the operation of
the inverter.
* Program Port
(not shown on wiring block diagram)
This USB port is for internal use only. This CANNOT be used for charging Smart phones or USB
powered devices. Mis-use of this port can potentially damage the unit and is not covered by the
warranty. This port is located on the Display Panel and is also located below the
Ignition Start Port
on 2000W models.
* CAN BUS Port
(not shown on wiring block diagram)
This is for unit communication through CAN interface. Mis-use on this port can potentially damage
the unit and is not covered by the warranty. This port is located on the Display Panel and is also