INT
Off
AC Bypass only, Charger set to Off.
CHG
Off
By-Pass
Mode Display
Unit is running in By-Pass mode. Both AC Output Hardwire and AC Output Socket are
connected to AC Input Source.
- AC Charger is disabled. When this setting is used, a separate AC Charger or other
battery charging source is required to charge the battery.
- Battery icon shows estimated battery capacity
- Inverter is in disabled.
- Display shows battery voltage, DC Charging current (0A), AC Input Power.
-
‘Power’ indicator – On.
-
‘AC Output’ indicator – On (AC Output Switch is turned On, AC Output is On).
-
‘AC Output’ indicator – Off (AC Output Switch is turned Off, AC Output is Off).
Note: Press and hold ‘ESCAPE’ button for 5 seconds to toggle AC Output Switch
On/Off.
-
‘Status’ indicator – solid green.
Note: ‘Power’ button function is disabled in this stage.
Blackout
When a blackout occurs, unit will not provide AC Backup. Display remains On for 10
seconds with the following appearance:
- Display remains to show battery voltage, DC Current discharge from battery (0A), AC
Output Power (0W)
- Battery icon shows estimated battery capacity.
- Inverter is disabled.
-
‘Power’ indicator - On,
-
‘AC Output’ indicator – Off (AC Output is not available due to the inverter being set to
Off.
-
‘Status’ indicator – Off
After 10 seconds, Display and unit will turn Off.
Press and hold the ‘Power’ button for 1 second to turn On the display .to check the
battery status.
If AC Input Source is detected, unit will switch back to By-Pass Mode automatically in
about 10 seconds. During the 10 second period,
‘Power’ indicator turns On and ‘Status’
indicator remains Off.
b) Charger Functions
Battery Charging Cycle