For  safe  and  optimum performance,  the Inverter-Charger  must be  used  properly.  Carefully  read  and 
follow  all  instructions  and  guidelines  in  this  manual  and  give  special  attention  to  the 

CAUTION

  and 

WARNING

 statements. 

PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE 

Disclaimer 

While  every  precaution  has  been  taken  to  ensure  the  accuracy  of  the  contents  of  this  guide, 

KISAE  Technology 

assumes  no  responsibility  for  errors  or  omissions.  Note  as  well  that 

specifications and product functionality may change without notice. 

Important  

Please  be  sure  to  read  and  save  the  entire  manual  before  using  your 

KISAE  Sinewave 

Inverter-Charger. 

Misuse  may  result  in  damage  to  the  unit  and/or  cause  harm  or  serious 

injury. Read manual in its entirety before using the unit and save manual for future reference. 

Model Numbers 

120VAC Series : 

  BIC1220080   Inverter-Charger 12V / 2000W / 80A - 120VAC (NEMA 5-20) 
  BIC1230100  Inverter-Charger 12V / 3000W / 100A - 120VAC (NEMA 5-20) 
  BIC2420040  Inverter-Charger 12V / 2000W / 40A - 120VAC (NEMA 5-20) 
  BIC2430050  Inverter-Charger 12V / 3000W / 50A - 120VAC (NEMA 5-20) 
 

230VAC Series : 

BIC1220080i-EU  Inverter-Charger 12V / 2000W / 80A - 230VAC (Schuko Socket - CEE 7/4) 
BIC1220080i-UK  Inverter-Charger 12V / 2000W / 80A - 230VAC (British Socket - BS1363) 
BIC1220080i-AU  Inverter-Charger 12V / 2000W / 80A - 230VAC (Australia Socket 

– NS/NZS3112)

 

BIC1230100i-EU  Inverter-Charger 12V / 3000W / 100A - 230VAC (Schuko Socket - CEE 7/4) 
BIC1230100i-UK  Inverter-Charger 12V / 3000W / 100A - 230VAC (British Socket - BS1363) 
BIC1230100i-AU  Inverter-Charger 12V / 3000W / 100A - 230VAC (Australia Socket 

– NS/NZS3112)

 

BIC2420040i-EU  Inverter-Charger 24V / 2000W / 40A - 230VAC (Schuko Socket - CEE 7/4) 
BIC2420040i-UK  Inverter-Charger 24V / 2000W / 40A - 230VAC (British Socket - BS1363) 
BIC2420040i-AU  Inverter-Charger 24V / 2000W / 40A - 230VAC (Australia Socket 

– NS/NZS3112)

 

BIC2430050i-EU  Inverter-Charger 24V / 3000W / 40A - 230VAC (Schuko Socket - CEE 7/4) 
BIC2430050i-UK  Inverter-Charger 24V / 3000W / 40A - 230VAC (British Socket - BS1363) 
BIC2430050i-AU  Inverter-Charger 24V / 3000W / 40A - 230VAC (Australia Socket 

– NS/NZS3112)

 

Document Part Number   

MUBIC Rev A 

Service Contact Information 

Email: 

[email protected] 

Phone : 

1-877-897-5778 

Web : 

www.kisaepower.com

 

 

 
 

 

 

WARNING: 

This product can expose you to chemicals, including Di (2-ethylhexyl) phthalate (DEHP)

 

which is known 

to  the  State  of  California  to  cause  cancer, birth  defects  or  other  reproductive

 

harm.  For  more  information,  go  to 

www.p65warnings.ca.gov

 

ADVERTENCIA 

Este producto puede exponerlo a productos químicos, incluidos Di (2-etilhexil) ftalato (DEHP)

 

que 

el estado de California sabe que causa cáncer, defectos de nacimiento u otros daños

 

reproductivos. Para obtener 

más información, vaya a www.p65warnings.ca.gov

 

 

Содержание 120V 12V-2000W-80A

Страница 1: ...V 2000W 80A BIC1220080 12V 3000W 100A BIC1230100 24V 2000W 40A BIC2420040 24V 3000W 50A BIC2430050 230V Series 12V 2000W 80A BIC1220080i 12V 3000W 100A BIC1230100i 24V 2000W 40A BIC2420040i 24V 3000W...

Страница 2: ...1363 BIC1220080i AU Inverter Charger 12V 2000W 80A 230VAC Australia Socket NS NZS3112 BIC1230100i EU Inverter Charger 12V 3000W 100A 230VAC Schuko Socket CEE 7 4 BIC1230100i UK Inverter Charger 12V 30...

Страница 3: ...mable fumes or gases such as propane tanks or large engines AVOID covering the ventilation openings Always operate unit in an open area Prolonged exposure to high heat or freezing temperatures will de...

Страница 4: ...Page 4 Table of Contents 1 INTRODUCTION 5 2 PRODUCT DESCRIPTION 5 3 UNDERSTANDING THE UNIT 6 4 INSTALLING THE UNIT 10 5 UNIT OPERATION 13 6 TROUBLESHOOTING 24 7 SPECIFICATIONS 25 8 WARRANTY 27...

Страница 5: ...utility power is interrupted This manual will explain how to use this unit safely and effectively Please read and follow these instructions and precautions carefully 2 PRODUCT DESCRIPTION The Sinewave...

Страница 6: ...follow these instructions can damage the unit and could also result in personal injury or loss of life CAUTION Before beginning unit installation please consider the following The unit should be used...

Страница 7: ...y Actual run times may vary on battery type used b DC Fuse or Circuit Breaker DC rated fuse or DC rated circuit breaker connected along the DC positive line is required Fuse Circuit Breaker Rating 12V...

Страница 8: ...ent sizes refer to the applicable installation code for the DC grounding detail In marine applications the main AC DC ground bonding may require galvanic isolators to avoid galvanic corrosion Check yo...

Страница 9: ...t is used to connect to the Multi Function Display of the unit k Multi Function Display The display is used to provide unit information and for setting and programming the unit l BTS Port The port is...

Страница 10: ...Input terminals will damage the unit and it cannot be repaired Damage caused by reverse polarity connection is not covered by the warranty IMPORTANT Field wiring DC terminals tightening torque 12 13 N...

Страница 11: ...secure the AC Input wire For AC Output Hardwire Connections Insert the AC Input cable through the AC Output Strain relief h on the unit Connect the AC Sub Panel AC Ground wire to the AC Output Ground...

Страница 12: ...rovides AC Input power to the unit If AC input source is available the Status LED amber will flash for about 10 seconds indicating the AC Input source is available It will then turn to solid green or...

Страница 13: ...nput is available this Power button cannot be used to turn OFF the unit Menu SET e button can be used to view the unit setting ESCAPE h button Press and hold for 5 seconds to turn OFF or ON the AC Out...

Страница 14: ...Battery Default Bulk Charge Float Voltage is 14 2V 13 8V Default Flooded Battery Default Bulk Charge Float Voltage is 14 4V 13 5V AGM Battery Default Bulk Charge Float Voltage is 14 3V 13 4V Lithium...

Страница 15: ...the last bar flashing indicates the unit is running in By Pass mode and the battery is in charging process The charging stages are indicated by the number of bars 4 bars in solid indicates the battery...

Страница 16: ...arting Check if any object has blocked the air flow of the unit E05 When unit is in Battery Inverter mode Input battery voltage is low and warning occurs Recharge battery as unit will shutdown shortly...

Страница 17: ...y Note During blackout Power button can be used to temporarily turn inverter Off to save battery power if AC Output power is not required INT ABU Automatic Backup with Charger set to Off CHG OFF By Pa...

Страница 18: ...battery capacity Inverter is disabled Power indicator On AC Output indicator Off AC Output is not available due to the inverter being set to Manual Backup Mode MBU Status indicator Off After 10 secon...

Страница 19: ...acity Inverter is disabled Power indicator On AC Output indicator Off AC Output is not available due to the inverter being set to Manual Backup Mode MBU Status indicator Off After 10 seconds Display a...

Страница 20: ...ON Inverter Only Unit is running as inverter only no By Pass function CHG OFF ON This setting is specially designed so that the AC load connected to AC Output is always getting clean sinewave power f...

Страница 21: ...Switch On Off Status indicator solid green Note Power button function is disabled in this stage Blackout When a blackout occurs unit will not provide AC Backup Display remains On for 10 seconds with...

Страница 22: ...e total AC current draw from the shore power during the By Pass Charger mode to avoid tripping the shore power Branch Breaker Absorption to Float Stage Current Setting 12V 3000W 20A 15A 10A Default 5A...

Страница 23: ...d Battery Disconnect Functions Battery Under and Over Voltage Setting Battery Low Disconnect voltage has selectable range 10 5 12 0V 0 1V steps Default 10 5V The Battery Low Disconnect Voltage has to...

Страница 24: ...utput switch is turned Off Press and hold the ESCAPE button for 5 seconds to turn On the AC Output AC Input Source is available but is out of the acceptance range by the unit Check AC Input Source Uni...

Страница 25: ...rt RJ12 Inverter Mode Battery Voltage DC Current AC Output Power Charger Mode Charging Voltage Charging Current AC Input Power Running as Battery Charger Charging Voltage Range 13 8 14 8 VDC Float Vol...

Страница 26: ...Mode Battery Voltage DC Current AC Output Power Charger Mode Charging Voltage Charging Current AC Input Power Running as Battery Charger Charging Voltage Range 27 6 29 6 VDC Float Voltage Range 26 0 2...

Страница 27: ...e if products are deemed non working or malfunctioning the product may be returned to the purchasing store within 30 days of original purchase Any defective unit that is returned to manufacturer withi...