background image

-22-

CAUTION

The usage of the battery 

It will explode to cause a severe accident if the battery used in a wrong way. 

Remove the negative terminal when servicing the generator.

NOTE

Breaker can prevent the electric shock. If need to replace, please replace one 

that has equal degree and performance.

-11-

4. WARM-UP PROCEDURE

1. Check the fuel before every start. 

2. Check if the engine oil reaches the scale of stipulating.

3. Check the water lever, and fill the cooled-water full.

4. Check the fan strap's degree of tightness

5. Set the main switch to OFF.

6. Turn the engine start key to START position.

7. Warm-up time is about 3-5 minutes.

8. Speed controller has adjusted well before transporting. So don't adjust it at 

random, or it will cause the engine rotation speed too high or too low.

9. The battery is optional for generator, to install right battery according with the 

generator before start.

2. Judge and elimininate troubles

S

ta

rt

 m

o

to

ru

n

  

b

u

d

o

e

s

n

't 

s

ta

rt

S

ta

rt

 m

o

to

d

o

e

s

n

't 

ru

n

 

o

it

's

 s

p

e

e

d

 i

s

 s

o

 s

lo

w

A

m

b

ie

n

te

m

p

e

ra

tu

re

is

 v

e

ry

 l

o

w

Battery leakage

Battery unclamped or rut

Start switch badness

Starter badness

The wire breaks

No fuel oil

Fuel oil cleaner walled up

Air in the oil pipe

Liquid measure

Install after cleaning

Repair

Replace

Replace

Repair

Fill oil 

Clean , and replace fuel oil cleaner

Empty air

S

to

au

to

m

at

ic

ro

ta

te

 s

pe

ed

do

es

n'

t r

is

e

Some water accumulated in

the fuel system is frozen. 

Fuel is frozen

Fuel winding does not work

Empty air

Mend the engine

Replace air cleaner element

Use winter oil, or choose the applicable

viscosity oil according to the freeze area

Check the fuse, if disconnection, replace

it ,check and replace winding if necessary

Heat, empty fuel oil tank ,fuel oil cleaner

and water in oil pipe

Replace fuel oil cleaner element, clean or replace filter

Bad Air around pipe 

Fuel oil cleaner walled up

Badness water of pipe oil

Air cleaner is clogged.

E

n

g

in

e

 d

o

e

s

n

't 

ru

n

The earth terminal is imperfect

Содержание KDE12EA

Страница 1: ...WUXI KIPOR POWER CO LTD GENERATOR R Single phase KDE12EA KDE12STA Three phase KDE12EA3 KDE12STA3...

Страница 2: ......

Страница 3: ...it 3 For information about the engine operation and maintenance please see our engine s manual 4 Laymen especially the children can not realize the danger they should keep away from the generator 5 Pl...

Страница 4: ...Servicing 4 Warm up Procedure 5 Starting up Procedure and running 6 Stop Procedure 7 The Functions of the Digital Panel 8 Electrical appliance 9 Malfunction and Countermeasures 10 Simplified Troubles...

Страница 5: ...ntinuous running E Open frame type ST Super silence Rotation Shaft Steel Connection E 200 ST 310 340 Transistorized self excitation and constant voltage AVR Rated Frequency Hz Rated Power KVA Max Powe...

Страница 6: ...the working hours in noisy condition Furthermore the sound exposure level varies among different countries The conditions of generator rated output Altitude 0 m Ambient temperature 25 Relative humidi...

Страница 7: ...in the cable is bigger than the allowable current it will become over hot and the cable will be burnt If the cable is long and thin the input voltage of the electric appliance will be not enough caus...

Страница 8: ...s Start the engine after closing the door for safety and noise control 2 2 Initial start check CAUTION Stop the engine at once and check for the fault if the warning lamps light CAUTION Check the unit...

Страница 9: ...e engine oil 2 Check the cooling water in radiator 3 Check the fuel 4 Check the fuel pipe 5 Check the battery voltage 6 Check the grounding protection 7 Check the water leakage and oil leakage 8 Check...

Страница 10: ...to avoid lacking of engine oil to cause fault inspect the oil level and add engine oil if necessary CAUTION Radiator Be careful of the hot radiator It s very dangerous to open the radiator cover when...

Страница 11: ...on or replacement of the belt 4 Check the fuel Check the fuel level if normal before running the generator Often open the drain plug in the fuel tank to drain the sediment and impurity CAUTION Tighten...

Страница 12: ...same with the factory setting 1 Sampling wire disconnects 2 Abnormal frequency Too high or too low 3 Abnormal fuel system the engine rotating speed is unstable Check the fuel system P 02 Check the vo...

Страница 13: ...Reason Bad voltmeter Bad AVR Loading short circuit Rotor circuitry break Engine circuitry is burnt Bad voltmeter Bad AVR Loading is over Generator cable is burnt Rotation speed is too low Bad voltmete...

Страница 14: ...with bad matter such as fuel oil cooling water solvent filter and battery according to the law 12 Shut down the power after removing the battery cathodal wire when checking and maintaining generator...

Страница 15: ...or before start 2 Judge and elimininate troubles Start motor run but doesn t start Start motor doesn t run or it s speed is so slow Ambient temperature is very low Battery leakage Battery unclamped or...

Страница 16: ...e careful to fill fuel and prevent fuel overflowing Wipe up the overflowing fuel immediately Flame and fire are forbidden near the generator CAUTION This guide is intended to give brief information fo...

Страница 17: ...es will be burned out and damaged 4 Connect the equipment to the generating set in order For the matter of the motor load firstly the heave duty motor should be connected and then the light duty motor...

Страница 18: ...resuming operation CAUTION 6 STOP PROCEDURE 1 Set the main switch to OFF 2 Turn the breaker to the OFF 3 Turn the start switch to the STOP position after running for 1 3 minutes with zero load then th...

Страница 19: ...abinet Converter cabinet Halide lamp Projection lamp 15 Knob function ITEM switch the content of display the content include battery voltage running time output frequency output current generator volt...

Страница 20: ...ltage Indicating generator voltage Generator running Indicating the existence of electrical power Running trouble Indicating running trouble check it according to the code map list The indication lamp...

Отзывы: