-31-
2. Model Specifications:
E: Open-frame type ST: Super silence
A: Digital panel 3: Three-phase
MODEL
ITEM
E
n
g
in
e
Mode
Type
Dispacement (ml)
Bore x Stroke (mm)
Fuel
Oil Tank Capacity (L)
Decompression
Standard Power (KVA)
Fuel Tank Capacity (L)
Starting Mode /Battery capacity
KM2V80
794
80 X 79
0 ~ 35 Diesel
2.27
23
12 14.5 12 14.5
12V Electric Starter /36AH or 50AH
26
Two-cylinder, V-twins, Air-cooled, 4-stroke, Bow-wave type
-2-
3. Noise instruction:
The noise list indicates the noise emission level while not the safe working noise
level. Although the noise emission level is related to the sound exposure level, it is
not the judging standard for whether applying noise protection.
Factors affect the practical noise level including: the ambient condition and other
noise source, such as the quantity of working machine or the working hours in
noisy condition. Furthermore, the sound exposure level varies among different
countries.
The conditions of generator rated output:
Altitude: 0 m Ambient temperature: 25 Relative humidity: 30%
Ambient modified coefficient: C (Relative humidity 30%)
Note: When the relative humidity is 60%, the modified coefficient is C-0.01
When the relative humidity is 80%, the modified coefficient is C-0.02
When the relative humidity is 90%, the modified coefficient is C-0.03
When the relative humidity is 100%, the modified coefficient is C-0.04
Counting example:
When the rated power of generator is P =5KW, altitude is 1000m, ambient
N
temperature is 35
, relative humidity is 80%, the rated power of generator is:
P=P
(C-0.02) = 5
(0.82-0.02) = 4KW
N
2. Modified coefficient table of ambient condition power
Ambient temperature (
)
Altitude
(m)
0
500
1000
2000
3000
4000
25
1
0.93
0.87
0.75
0.64
0.54
30
0.98
0.91
0.85
0.73
0.62
0.52
35
0.96
0.89
0.82
0.71
0.6
0.5
40
0.93
0.87
0.80
0.69
0.58
0.48
45
0.90
0.84
0.78
0.66
0.56
0.46