31
6.5
Damage to the fan or the rotation
sensor
The alarm occurs when the fan speed sensor
or the fan itself is damaged, based on the
voltage capacity on the fan control output.
The controller turns off the fan.
The alarm can be reset by acknowledging the
alarm on the screen or only and powering up
the regulator.
The furnace door is open
This is called a silent alarm prompt that will
occur when the furnace door opening sensor
is triggered. The alarm is reset by closing the
door or confirming the alarm on the screen.
Other functions of the regulator
6.6
Power failure
7
In the event of a power failure, the
regulator will return to the operating
mode in which it was before its
disappearance.
7.1
Replacement of parts and
components
7.2
Replacing the mains fuse
The mains fuse is located inside the
controller housing. The fuse may only be
replaced by a suitably qualified person after
disconnecting the mains supply. Use time-
delay fuses, porcelain, 5x20 mm, with a
nominal burnout current of 6.3 A and a
voltage of 230
V.
In order to remove the fuse, use a flat-blade
screwdriver to lift the fuse holder and pull
out the fuse.
Replacing the control panel
It is not recommended to replace the control
panel itself because the program in the panel
must be compatible with the program in the
rest of the regulator.
Sodtware update
The program replacement can be performed
with a microSDHC memory card only (FAT32
format, max. 32 GB).
The software may only be
replaced by an authorized person,
observing all precautions against
electric shock!
To replace the program, disconnect the
power supply to the controller and insert the
memory card into the indicated panel slot.