The new software should be saved on the
memory card in the * .pfc format in the form
of two files: the file with the panel program
and the file with the program for the
controller A module. Place the new software
directly on the memory card and do not put
the data in a subdirectory. Then reinstall the
panel in the controller housing and connect
the power supply. Enter the menu:
8
General settings
→
Software update
and replace the program first in the A
module of the regulator and then in the
regulator's panel.
Description of possible faults
Malfunction
symptoms
Tips
The
display
shows
no
signs
of
operation of
the
device
despite
connecting to
the network.
Check if the mains fuses have not
been
blown
and
replace
if
necessary - point 7.1
Burner fan is
not working.
Check if the STB safety
temperature limiter input jumper
is on terminals 1-2, (the jumper
should be installed only if the
temperature
limiter
is
not
connected)
If the STB temperature limiter is
reset to the starting position
manually, the limiter should be
unlocked - point Check the
burner fan and replace if
necessary.
The exhaust
fan
is
not
working.
Check if the mains fuse of the
exhaust fan is not blown and
replace if necessary.
Check whether the hall sensor
has not been damaged.
Check the exhaust fan and
replace if necessary.
The
fuel
feeder
does
not work /
does not feed.
Check that the feeder wires are
properly connected
to
the
terminals.
If the STB temperature limiter is
connected to terminals 1-2,
check that the circuit has not
been cut off due to overheating
of the furnace.
Check if the feeder motor is not
damaged.
If you can hear the engine
running and the fuel is not fed,
check the feeder in accordance
with the furnace manual.
Fuel is not
burned
out.
There
are
unburned fuel
particles
in
the ash. Fuel
burns up with
a lot of smoke
or the burner
goes out.
Check user settings for Power
modulation.
Temperature
is not being
measured
correctly.
Check:
is there a good thermal contact
between the temperature sensor
and the measured surface,
that the sensor cable does not run
too close to the network cable,
whether the sensor is properly
connected to the terminal,
whether the sensor is not damaged
Change log: