FP 75 E
Issue: 08/2012
51
Annually
Component
What is to do?
Sound reproducer
Lubricate the pressure roller ball bearings with a drop of
Cardan oil, type 8657.
Do not use any other lubricant!
Lubricate the sound drum shaft with 1 drop of Esso
universal oil.
X
NOTE
Z
Cardan oil is very pasty therefore the ball bearings will be retarded for a proper film
run. By getting move the guide roller with one finger, the roller has to stop at last
after a half of turn. Otherwise you have to clean the bearing and then fill it with
Cardan oil.
Z
You must not use any oil or grease!
Water cooling
Empty and clean and refill coolant. Check whether pump
and refrigeration system are sealed and working properly.
6 .4
Repair
6 .4 .1 Changing the Pilot Lamp
ATTENTION
Before opening the shutter housing, wait until the
shutter stands still!
• Remove the shutter housing.
• Put screw driver behind the lamp socket (arrow)
and lift the lamp out of the socket.
• Push the new pilot lamp into the socket and
close shutter housing.
•
Repair and Adjustments