26
FIGURE 18 – Manual and Millivolt Pilot Flames
FIGURE 19 – Millivolt Models
1. Remove the Universal Bottom before installing Kingsman Multiview Burner system by removing 4 screws.
2. Position burner assembly as per unit configuration (eg. left corner, right corner, peninsula, etc.)
3. Tilt burner assembly so valve is at an angle to the fireplace and lower into position.
4. Line the 4 holes on the burner assembly as shown on the diagram with the 4 holes on the fireplace and screw into place
with 1/2” DT Screws.
5. Install log support plates as shown in the lower diagram. (Make sure the log support plate with the cut out is placed on
the side where the ODS Pilot is located.)
NOTE: When installing Burner assembly into a corner installation it is very important that the NON FLAME END of the
burner assembly is facing the side of the enclosure that is built in.
FIREBOX BOTTOM
ODS PILOT
LOCATION
NON FLAME END
OF BURNER
ASSEMBLY
(SEE NOTE)
BURNER
INSTALLATION
HOLES
Figure 17
UNIVERSAL
BOTTOM
NOTE: LOG LOCATOR
PIN ORIENTATION
INSTALLING – MVFB4040 Burner Systems
Warning:
Failure to position parts in accordance with these diagrams or failure to use only part specifically
approved with this heater may result in property damages or personal injury.
CLEANING AND SERVICING OF
BURNER / ODS PILOT
It is recommended to annually inspect and clean the unit to
prevent malfunction and / or sooting. This operation should
be performed by your dealer or a qualified technician.
1.
Remove fireplace hood and screen. (Refer to
Installation
of Door Screen and Hood,
page 30
.)
2.
Remove log set, handling carefully by holding gently at
each end. (Refer to
Log Placement,
page 26
.) Gloves are
recommended to prevent skin irritation from ceramic.
Annual Cleaning / Inspection
•
Do not use cleaning fluids to clean logs or any part of the
heater.
•
Use a soft bristle brush or a vacuum with brush attachment.
•
Vacuum loose particles and dust from burner ports, valve
and blower compartments.
•
Vacuum any accumulation of lint from primary mixing
tube.
•
Inspect ODS pilot for operation, accumulation of lint at the
air inlet holes.
•
Verify flame pattern and log placement for proper
operation.
•
Verify that all ports ignite and cross over smoothly from rear
to front burner.
WARNING
Turn off heater and allow to cool before cleaning. Only a
qualified service technician should service and repair appliance.
Failure to keep primary air openings clear, may result in
sooting and property damage.