BAY PENINSULA FRAMING SPECIFICATIONS
FRAMING
Using 2x4s frame to local building codes.
DO NOT install against a vapour barrier or
exposed insulation.
Framing measurements have been adjusted to
accommodate a 1/2” thick finished wall.
FIGURE 9.
Combustible materials may be installed flush with
top and sides of fireplace.
It is not necessary to install a hearth with this
fireplace system. Objects placed in front of the
fireplace should be kept a minimum of 24” away
from the front face.
Fireplace bottom supplies you with two 6” x 8”
holes. The use of these holes depends on valve and
Fireplace location on riser or upper floor.
NOTE
If the unit is installed in a non conventional manner
not using 2x4 framing the nailing tabs may be
removed and the Heat Shields may be placed
directly against a combustible wall or partition.
When the unit is installed without nailing tabs the
unit must be secured to the floor using the holes
located in the bottom of the fireplace.
FIREPLACE ASSEMBLY
1. To mount Door Cover, Figure #10. Position Door Cover
over opening as shown in diagram and using 6 self tapping
screws secure onto fireplace. Check to see that door cover is
properly sealed.
2. Hang Heat Shield on top edge of Fireplace and secure with
self tapping screws. Heat Shield must be centered allowing a
1/2” clearance both sides of Fireplace for finishing material.
3. The Heat Shield is equipped with nailing tabs if 2x4
framing is used as shown in diagram. Level Fireplace and nail
or screw into place.
When not using 2x4 framing secure Unit with screws at
bottom (SEE ABOVE NOTE:)
NOTE: Use 8-18 x 3/4 DT screws for bottom of door cover.
NOTE: Holes for mounting sides of Heat Shield are not
pre-punched.
Note: Framing dimension shown is to
accept 1/2” facing material. The dimension
shown may be reduced depending on the
thickness of facing material up to 1”
Bay Peninsula Fireplace Shown
Figure 10
Figure 9
NOTE: The standoffs are non load bearing. When
installing a cabinet, a maximum weight of 250 lbs
can be installed on the 1/2” drywall lip (located
around the perimeter of the appliance).