AIR FOR COMBUSTION AND VENTILATION Cont.
VENTILATION AIR FROM INSIDE BUILDING
This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you
must provide two permanent openings: one within 12” of the ceiling and one within 12” of the floor on the wall connecting
the two spaces. You can also remove doors into adjoining
rooms. Follow the
National Fuel Gas Code NFPA 54/ANSI
Z223.1, Section 5.3, Air for Combustion and Ventilation
for
required size of ventilation for required size of ventilation
grills or ducts.
WARNING
Rework worksheet, adding the space of the adjoining
unconfined space. The combined spaces must have
enough fresh air to supply all appliances in both spaces.
Ventilation Grills into
adjoining room
Option 1
Ventilation Grills
into adjoining room
Option 2
Remove Door into
adjoining room
Figure 14