ZCVRB60 –Vented Chase- Style 1 – OPENING WITH NO GRILL
Vertical Venting must use
Firestop Spacer (Z58FS) or Attic Insulation
Shield and Sealant
SEALED ENCLOSURE
TOP VIEW
56”
MIN
76”
MIN
Open Area
Open
Area
VENTILATION PLATES MUST BE REMOVED
⚠
NOTE:
Minimum Opening is
200sq. inches of free air
.
⚠
NOTE:
If using insulation in
vented chase (i.e. for outside wall),
wall board / drywall is required to
support all insulation.
Vented chase must be clean and
free of all debris (i.e. loose
insulation, pieces of wood, etc.).
⚠
NOTE:
HEAT CANNOT BE
DISCHARGED INTO THE
WALLS, FLOOR, OR CEILING.
Heat must exit through the required
vented chase opening near the
ceiling.
Exterior wall is insulated
and drywalled.
200 SQ. IN. MINIMUM
1-7/8” MIN
with 3 Sides Open and
Cavity 19-1/4” Deep
2”
MIN with 3 Sides Open and
Recessed Cavity 15-3/4” Deep
200 SQ. IN. MINIMUM
2” MIN with 3 Sides
Open and Recessed
Cavity (15-3/4” Deep)
200 Sq. In. MIN
67” FRAMING I.D.
Ceiling / Enclosure Top
Open Area
Optional Attic
Insulation Shield
(Z58AIS, Z58AIS24)
76”
MIN
Ceiling / Enclosure Top
Open Area
76”
MIN
200 Sq. In. MIN
19-1/4”
67”
21