![Kingsman Fireplaces marquis MQZCVRB60LPE2 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/kingsman-fireplaces/marquis-mqzcvrb60lpe2/marquis-mqzcvrb60lpe2_installation-instructions-manual_1970936010.webp)
ZCVRB60 -Facing Requirements
An Unvented Chase requires Non-Combustible
covering (i.e., concrete board) over the front face of the
appliance.
A Vented Chase can have a Combustible covering (i.e.,
drywall) over the front face of the appliance.
Notice:
Granite, tile, or other facing materials are not
covered by the fireplace warranty. Natural stone, tile,
and other facing materials may crack or discolor (i.e.
yellowing of lighter colored materials).
NOTE: these issues can be avoided if the Chase is
Vented.
Televisions are not covered by fireplace warranty.
Notice: DurockR Brand Cement Board:
The
manufacturer recommends
CGC SheetrockR Brand
DurabondR 90 Setting- Type Drywall Compound
rather
than a ready-mix product for finishing.
When finishing the wall around the fireplace, it is critical
that the wall covering be fastened properly. It is acceptable
to pre-drill holes and use self-tapping screws which may be
used to fasten a backer for tile, marble, etc. Screws being
installed through non-combustible board should be self-
tapping type with a maximum length of 2 inches.
Do not drill or install longer screws (over 2”) as this
may damage internal components.
•
We recommend that CONCRETE BOARD (non-
combustible material) be tied in to the entire perimeter of the
fireplace for durability.
Finishing Recommendations
(Obtained from professional
construction contractors and finishers):
•
Frame unit with metal studs (minimum 20 gauge).
Wooden
studs may be used, but may cause drywall screws to
pop or pull due to wood studs drying out.
•
Minimum of 1/2” CONCRETE BOARD cement board (this
non-combustible
panel is ULC listed as a wall shield/floor
protector) and fasten to the entire perimeter framing.
•
Use fiberglass (mesh) tape for all joints in area of the
fireplace.
•
Use Yellow joint mud (contains high amounts of glue) –
two coats, finishing with one coat of green topping mud,
sand and prep for painting.
•
If not using a surround, a metal “L” Trim may be used to
finish perimeter of CONCRETE BOARD.
•
OTHER NOTES:
-
A full single shee
t of non-combustible board (no joints)
above the unit is recommended if possible.
-It is preferred to attach the non-combustible board to
framing only
and not directly to the unit to allow for
expansion and contraction during normal operation.
-Lighter colored painted surfaces may discolor due to heat
exposure.
UNVENTED CHASE:
NON-COMBUSTIBLE OVER
FACE OF APPLIANCE IS
REQUIRED.
SUGGESTED:
NON COMBUSTIBLE
MATERIAL SCREWED TO FRAMING
The area below the fireplace opening can have a combustible surface
(i.e. drywall, hearth).
Do not drill or install longer screws (over 2”)
as this may damage internal components
.
Suggested: Facing material
screwed to framing
VENTED CHASE:
COMBUSTIBLE OVER FACE OF
APPLIANCE IS ALLOWED.
10
Содержание marquis MQZCVRB60LPE2
Страница 47: ...Gas Conversion for Modulator PART C 47...
Страница 61: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 61...
Страница 69: ...Proflame 2 Remote Control 69...
Страница 71: ...71...