Burner System Removal for MQHB36/42/47
Removing Burner System / Access Cover for MQHBZDV36/42/47
If fireplace has been installed with optional CVCK (Clean View Circulating Kit) to service fan system or burner system controls, the
access cover and burner system pan will have to be removed.
Access Cover Removal
1. Remove door, logs, brick panels, false bottom, burner grate and burner from firebox.
2. Burner grate is fastened by 2 screws there is one right and left of grate assembly, remove screws and take out grate.
3.
MQHBZDV47 ONLY
. Lift false bottom up from screw alignment points and remove.
MQHBZDV47 skip steps 4 to 8.
4. Remove ember plates right and left of burner, ember plates are held in place by 2 screws each.
5. Loosen screws from burner retainer tabs and slide burner to the left to remove from orifice.
6. Remove rear log holder by removing the 2 screws on each side of log holder.
7. Remove left side log support by removing the 2 screws from side of support.
8. Remove left ember plate support by removing 2 screws at base of support.
9. Remove 10 screws holding access cover in place. Push down on one corner of access cover to break seal of cover, once loose
cover can be slid under firebox bottom to expose gas connection.
Removing Burner System
1. Disconnect gas line connection at burner system through access cover opening.
•
CAUTION: ALL WORK SHOULD BE PERFORMED BY A QUALI-
FIED AND CERTIFIED TECHNICIAN.
2. Remove extension knobs and wiring from face of gas valve.
3. Remove false bottom. Undo screws holding back log holder and
remove.
Remove screws from perimeter of burner system pan, lift pan at one
back corner and rotate pan up from back of firebox. Make sure when tilt-
ing up and removing burner system that all fan and valve control wiring is
disconnected at this time.
To re-install access cover / burner system remove old Mil Pac sealant
and apply new sealant. After new sealant is applied reverse removal pro-
cedure to re-install parts.
CAUTION: BEFORE STARTING REMOVAL OF PARTS TURN OFF GAS SUPPLY. DISCONNECT 110 VOLTS TO
FAN SYSTEM AND DISCONNECT 110 VOLTS TO ELECTRONIC IGNITION BURNER SYSTEM IF APPLICABLE
CAUTION: High temperature sealant has been applied to
access cover and burner system pan. New sealant will
have to be applied when re-installing access cover and
burner system to maintain the integrity of sealed com-
bustion chamber. Mil Pac part #840099 or Kingsman part
#1000-150MP sealant can be purchased from your
Kingsman retailer or distributor.
Warning: Failure to position the parts in accordance with these diagrams or failure to use only
parts specifically approved with this appliance may result in property damage or personal injury.
38
Содержание HBZDV4736
Страница 24: ...Non Combustible Header Attached Non Combustible Header Attached 24...
Страница 44: ...Gas Conversion for Modulator PART C WARNING WARNING 44...
Страница 47: ...Pilot Shield RSP1 RSP2 Qty 1 Shield Per Kit Back View 1 2 3 4 5 6 SLOTS SLOTS SLOTS SLOTS 47...
Страница 59: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 59...
Страница 60: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 60...
Страница 67: ...Proflame 2 Remote Control 67...
Страница 69: ...69...