MQHBZDV4236/MQRB4236 - HOW TO INSTALL CLEAN VIEW KIT (CVCK)
CAUTION: When using CVCK DO NOT INSTALL a Louver assembly.
1. Install optional fan kit (see Fan Instruction).
2. Fold two standoffs up into position and mount with supplied screws. (FIG 1)
3. Hang CVCK on top of fireplace retainer tabs and rotate down into position. (FIG 2)
4. Using the screws provided, fasten the non-combustible header onto the top of the CVCK assembly.
5. Using four supplied #6 screws, fasten CVCK kit to the inside frame of unit.
6. Kit is supplied with 2 valve extension knobs. Align the notches and slide the extensions onto valve knobs.
7. DO NOT brick or tile beyond the inside area of the CVCK kit to allow for removal of door.
NOTE:
ADDITIONAL ACCESS FOR GASLINE INSTALLATION AND FAN ELECTRICAL INSTALLATION- When CVCK is
installed in framing, remove 2 screws from the right and left side of the bottom panel. Once screws are removed, bottom
panel can be rotated forward for access to gas valve and fan system.
Clearance to Combustibles
Clearance to Combustibles
Back (from Standoffs)
0 inches/0 mm
Side (from standoffs)
0 inches/0 mm
Floor
0 inches/0 mm
Ceiling (from bottom of fireplace)
60 inches/150 cm
Top (from standoffs)
0 inches/0 mm
Top of 90 degree bend in Minimum
Enclosure of 45 to 46 inches
5 inches/128 mm
/ All Vent Systems
Top of 90 degree bend in
Enclosure over 46 inches
2 1/2 inches/64 mm / All Vent Systems
Top of Horizontal Pipe
1 1/2 inches/38 mm / All Vent Systems
Side & Bottom of Horizontal Pipe
1 inch/25.5mm / All Vent Systems
Vertical Vent Pipe
1 inch/25.5mm / Kingsman Vent Systems
Vertical Vent Pipe
1 1/4 inch/32mm / Simpson/AmeriVent/Selkirk
Direct Temp Systems
⚠
WARNING:
Failure to position the parts in accordance with these diagrams or failure to use only parts specifically
approved with this appliance may result in property damage or personal injury.
NOTE:
When using the
Clean View Kit (CVCK)
and installing optional
electrical components
(i.e. Remote Controls,
variable speed control,
and or fan modules)
locate them in the Clean
View access area,
unless other shielding
devices like our IPI
Component box is used.
(NOTE -Floor) if installing the
appliance directly on carpeting
or other combustible materials
other than wood flooring, the
appliance shall be installed on a
metal or wood panel, the full
width and depth of the
appliance. Carpet may extend 1
inch above the floor of
appliance.
For units with CVCK (Clean
View Circulating Kit) see framing
with CVCK to establish floor
heights.
19
Содержание HBZDV4736
Страница 24: ...Non Combustible Header Attached Non Combustible Header Attached 24...
Страница 44: ...Gas Conversion for Modulator PART C WARNING WARNING 44...
Страница 47: ...Pilot Shield RSP1 RSP2 Qty 1 Shield Per Kit Back View 1 2 3 4 5 6 SLOTS SLOTS SLOTS SLOTS 47...
Страница 59: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 59...
Страница 60: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 60...
Страница 67: ...Proflame 2 Remote Control 67...
Страница 69: ...69...