MQHBZDV4236/MQRB4236 - Framing for your Gas Fireplace
Framing Specifications
1. Cold climate installation recommendation: When installing this fire-
place against non insulated exterior wall or chase, it is recom mended
that the outer walls be insulated to conform to applicable insulation
codes. Drywall must be installed over insulation to prevent contact of
insulation and unit.
2. Choose fireplace location and frame in accordance with the fireplace
framing dimensions specified (See Framing Diagrams). Bend nailing
tabs forward on left and right of unit and place fireplace into framed
enclosure. This allows for 1/2” in front of framing tabs for finishing
materials.
3. Drywall or other material can extend flush with the appliance on the
bottom, sides and top of fireplace. (louvered models only)
MQHBZDV42/MQRB4236 louvered
4. When installing horizontal with a 90 degree bend maintain a minimum
of two and a half (2.5”) inches above the bend in enclosures.
5. For a fireplace with louvers combustible floor can raise 1” above
the bottom of the fireplace. For a fireplace with HB42CVCK
(Clean view Circulating Kit) floor or hearth can raise 7” above
the bottom of the fireplace with portions being combustible and
non combustible. See drawing on following page.
6. When installing MQHB42SW surround,the fireplace must be
raised a minimum of 3 1/2” above the finished floors, to accom-
modate the wall surround. The fireplace may be raised higher
but the 60” clearance measured from the bottom of the fire-
place to the ceiling must be maintained at all times. (i.e. For an
8 ft. ceiling the unit can be raised only 36 inches.)
It is recommended for
Propane Horizontal Installations
that the venting should be a minimum of one foot vertical off the flue
before the elbow on any horizontal runs of one foot or greater. This allows for cleaner combustion and greatly reduces carboning
and cleaning of glass. (Does not apply to Back Flue Models).
MQHBZDV42/MQRB4236 WITH HB42CVCK
(CLEAN VIEW CIRCULATING KIT)
17
Содержание HBZDV4736
Страница 24: ...Non Combustible Header Attached Non Combustible Header Attached 24...
Страница 44: ...Gas Conversion for Modulator PART C WARNING WARNING 44...
Страница 47: ...Pilot Shield RSP1 RSP2 Qty 1 Shield Per Kit Back View 1 2 3 4 5 6 SLOTS SLOTS SLOTS SLOTS 47...
Страница 59: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 59...
Страница 60: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 60...
Страница 67: ...Proflame 2 Remote Control 67...
Страница 69: ...69...