Conversion Kit Instructions – PART A
Kit Number
Appliance
Description
Pilot Orifice
Burner Orifice
Brass (1000-255)
Brass
Nipple
Air
Shutter
Hi/Lo
Regulator
3632HB -CKLP
MQHBZDV3636LP
Propane Conversion
-Millivolt-
1001-P167SI
#30 (977.167)
#51
1000-253closed 5/16”
1001-P202SI
(0.907.202)
3632HB –CKLPI
MQHBZDV3636LPE Propane Conversion
-IPI -
1001-P168SI
#35 (977.168)
#51
1000-253closed 5/16”
1002-P014SI
(0.907.014)
3632HB –CKLP2
MQHBZDV3636LPE2 Propane Conversion
-IPI -
1001-P168SI
#35 (977.168)
#51
1000-253closed 5/16”
1002-P012SI
(907.012)
3632HB -CKNG
MQHBZDV3636N
NG Conversion
-Millivolt-
1001-P165SI
#51 (977.165)
#36
1000-253closed 3/16”
1001-P201SI
(0.907.201)
3632HB –CKNGI
MQHBZDV3636NE
NG Conversion
- IPI -
1001-P166SI
#62 (977.166)
#36
1000-253closed 3/16”
1002-P016SI
(0.907.016)
3632HB –CKNG2
MQHBZDV3636NE2
NG Conversion
- IPI -
1001-P166SI
#62 (977.166)
#36
1000-253closed 3/16”
1002-P013SI
(907.013)
4232HB-CKLP
MQHBZDV4236LP
Propane Conversion
-Millivolt-
1001-P167SI
#30 (977.167)
#51
1000-253closed 5/16”
1001-P202SI
(0.907.202)
4232HB –CKLPI
MQHBZDV4236LPE Propane Conversion
-IPI -
1001-P168SI
#35 (977.168)
#51
1000-253closed 5/16”
1002-P014SI
(0.907.014)
4232HB –CKLP2
MQHBZDV4236LPE2 Propane Conversion
-IPI -
1001-P168SI
#35 (977.168)
#51
1000-253closed 5/16”
1002-P012SI
(907.012)
4232HB -CKNG
MQHBZDV4236N
NG Conversion
-Millivolt-
1001-P165SI
#51 (977.165)
#36
1000-253closed 3/16”
1001-P201SI
(0.907.201)
4232HB –CKNGI
MQHBZDV4236NE
NG Conversion
- IPI -
1001-P166SI
#62 (977.166)
#36
1000-253closed 3/16”
1002-P016SI
(0.907.016)
4232HB –CKNG2
MQHBZDV4236NE2
NG Conversion
- IPI -
1001-P166SI
#62 (977.166)
#36
1000-253closed 3/16”
1002-P013SI
(907.013)
4236RB-CKNG
MQRB4236N
NG Conversion
-Millivolt-
1001-P165SI
#51 (977.165)
#36
1000-P201VE
Hex
3/16”
1001-P201SI
(0.907.201)
4236RB-CKNGI
MQRB4236NE
NG Conversion
- IPI -
1001-P166SI
#62 (977.166)
#36
1000-P201VE
Hex
3/16”
1002-P016SI
(0.907.016)
4236RB-CKNG2
MQRB4236NE2
NG Conversion
- IPI -
1001-P166SI
#62 (977.166)
#36
1000-P201VE
Hex
3/16”
1002-P013SI
(907.013)
4236RBT-CKLP*
MQRB4236LPT
Propane Conversion
-Millivolt-
1001-P167SI
#30 (977.167)
#53
1000-P201VE
Hex
1/4”
1001-P201SI
(0.907.201)
4236RBT –CKLPI*
MQRB4236LPTE
Propane Conversion
-IPI -
1001-P168SI
#35 (977.168)
#53
1000-P201VE
Hex
1/4”
1002-P016SI
(0.907.016)
4236RBT –CKLP2*
MQRB4236LPTE2
Propane Conversion
-IPI -
1001-P168SI
#35 (977.168)
#53
1000-P201VE
Hex
1/4”
1002-P012SI
(907.012)
*NOTE:
The
MQRB4236N
CANNOT BE CONVERTED TO LP.
If the MQRB4236NT you wish to convert to LP has a serial number less than #4708You MUST order the
4236RB-SRKP upgrade kit. (See Gas Conversion –Part A drawings which follow)
4236RBT-CKNG
MQRB4236NT
NG Conversion
-Millivolt-
1001-P165SI
#51 (977.165)
#42
1000-P201VE
Hex
1/32”
1001-P201SI
(0.907.201)
4236RBT-CKNGI
MQRB4236NTE
NG Conversion
- IPI -
1001-P166SI
#62 (977.166)
#42
1000-P201VE
Hex
1/32”
1002-P016SI
(0.907.016)
4236RBT-CKNG2
MQRB4236NTE2
NG Conversion
- IPI -
1001-P166SI
#62 (977.166)
#42
1000-P201VE
Hex
1/32”
1002-P013SI
(907.013)
4740HB-CKLP
HBZDV4736LP
Propane Conversion
-Millivolt-
1001-P167SI
#30 (977.167)
#49
1000-253closed Fully Open 1001-P201SI
(0.907.201)
4740HB-CKLPI
HBZDV4736LPE
Propane Conversion
-IPI -
1001-P168SI
#35 (977.168)
#49
1000-253closed Fully Open 1002-P016SI
(0.907.016)
4740HB-CKLP2
HBZDV4736LPE2
Propane Conversion
-IPI -
1001-P168SI
#35 (977.168)
#49
1000-253closed Fully Open 1002-P012SI
(907.012)
4740HB-CKNG
HBZDV4736N
NG Conversion
-Millivolt-
1001-P165SI
#51 (977.165)
#31
1000-253closed 5/16”
1001-P201SI
(0.907.201)
4740HB-CKNGI
HBZDV4736NE
NG Conversion
- IPI -
1001-P166SI
#62 (977.166)
#31
1000-253closed 5/16”
1002-P016SI
(0.907.016)
4740HB-CKNG2
HBZDV4736NE2
NG Conversion
- IPI -
1001-P166SI
#62 (977.166)
#31
1000-253closed 5/16”
1002-P013SI
(907.013)
Refer to “Gas Specifications Chart” for inlet pressures and input ratings. Clock meter to verify input rate. Place conversion label as close to converted gas
control as possible. Refer to lighting instructions to verify the normal operating sequence of the ignition system. IMPORTANT: Always check for gas leaks
with a soap and water solution. DO NOT USE OPEN FLAME FOR LEAK TESTING.
41
Содержание HBZDV4736
Страница 24: ...Non Combustible Header Attached Non Combustible Header Attached 24...
Страница 44: ...Gas Conversion for Modulator PART C WARNING WARNING 44...
Страница 47: ...Pilot Shield RSP1 RSP2 Qty 1 Shield Per Kit Back View 1 2 3 4 5 6 SLOTS SLOTS SLOTS SLOTS 47...
Страница 59: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 59...
Страница 60: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 60...
Страница 67: ...Proflame 2 Remote Control 67...
Страница 69: ...69...