Description
Read step size of specified program ( read step size display )
Bytes
7bh / program no / 5bh / checksum
Note
Sends ‘ Return step size of specified program ‘ block.
Description
Set step size of specified program ( + - )
Bytes
7ch / program step size / 5bh / checksum
Description
Read step period of specified program ( read period display )
Bytes
7dh / program no / 5bh / checksum
Note
Sends ‘ Return program step period’ block.
Description
Set step period of specified program ( + - )
Bytes
7eh / program step period / 5bh / checksum
Description
Read start value of specified program ( read start display )
Bytes
7fh / program no / 5bh / checksum
Note Sends
‘ Return start value of specified program ‘ block
Description
Set start value of specified program ( + - )
Bytes
80h / start value high byte / start value low byte / checksum
Description
Read finish value of specified program ( read finish display )
Bytes
81h / program no / 5bh / checksum
Note
Sends ‘ Return finish value of specified program ‘ block