background image

 

flue  outer  ring  and  into  the  outer  flue  tube.  Secure  in  place  with  self  tapping 
screws  and  then  cover  and  seal  the  joint  with  the  length  of  aluminium  tape 
supplied. Thread the fibreglass rope ring sealing gasket on to the flue. 

The  gas  supply  should  be  routed  from  the  meter  or  cylinder  to  a  point 
underneath  or  behind  the  appliance.  There  are  two  grommeted  apertures 
provided  for  gas  pipe  entry  in  the  convector  box.  From  this  point  route  the 
supply in 8mm diameter tubing to the combined pressure test point and isolator 
fitting. Any exposed pipe within the wall cavity should be wrapped, painted with 
bituminous paint or factory sheathed. Prior to connecting the burner to the gas 
supply it is advisable to blow out the pipe to clear any dirt that may be present 
and which could cause a blockage in the control valve or pilot.  

Remove  the  four  M5  screws  holding  the  convector  box  to  the  inner  fascia.  Lift 
the  heat  exchanger  and  flue  assembly  and  slide  the flue  assembly  through  the 
hole in the wall until the heat exchanger flange meets the convector box flange. 
Fix  the  heat  exchanger  through  the  convector  box  flanges  to  the  inner  fascia 
using the M5 bolts supplied. Replace the self tapping screws that secure the flue 
to  the  wall  plate.  Seal  the  flue  to  the  wall  plate  with  mastic.  Fit  the  terminal 
guard centrally over the terminal using screws and wall plugs. 

If  plasterwork  requires  to  be  made  good,  please  pay  attention  to  note  no.  3  on 
page 2 of these instructions 

Placing of Decorative Refractory Shapes 

 

Pour enough black ceramic granules to fill the space between the front air guide 
and  the  window  opening.  The  granules  should  finish  level  with  the  top  of  the 
window ledge. 

Two  packets  of  ‘Cotswold  Stone’  pieces  are  supplied  with  the  fire.  Open  the 
smaller packet containing twelve wedge shaped pieces.    

Place  ten  of  these  pieces  behind  the  rear  air  guide  with  the  longer  wedge 
pointing  downwards.  These  pieces  should  be  supported  by  the  rear  air  guide 
and by the board at the rear of the fire. See Figure 6. 

 

 

 

 

 

Place  the  two  remaining  pieces  on  top  of  the  brackets  at  either  end  of  the  air 
guides.  

Two  pieces  from  the  second  packet  should  be  placed  at  each  end  of  the  air 
guides.  They  should  rest  partly  on  the  front  air  guide  and  partly  on  the  black 
ceramic granules. See Figure 6. 

 

 

 

 

Figure 6 

Figure 7 

Содержание KBFP00RN

Страница 1: ...Heater MODEL NUMBER KBFP00RN INSTALLATION USER AND SERVICING INSTRUCTIONS THESE INSTRUCTIONS MUST REMAIN WITH THE USER This appliance is suitable for use on Natural Gas G20 at a supply pressure of 20...

Страница 2: ...s is not a Do it yourself product and it must be installed by a competent person 2 The Installation Instructions must be adhered to without exception 3 The heat from this appliance will cause the wall...

Страница 3: ...a Panel b Decorative trim and 4 magnets if ordered Inset Installations only a Wall plate must be used for Inset Installations APPLIANCE DATA KBFP00RN GAS TYPE NATURAL GAS SUPPLY PRESSURE 20 mbar HEAT...

Страница 4: ...r the inset installation 3 Flue Terminal Position The minimum distances permissible from the flue terminal to obstructions and ventilation openings are shown below DIMENSION TERMINAL POSITION MINIMUM...

Страница 5: ...gh the whole base of the builders opening fireplace recess or beneath the flue box b Project at least 275mm in front of the glass window panel c Project at least 150mm beyond each side of the edge of...

Страница 6: ...s with the approval of the designers of the dwelling Fitting This appliance can be installed either by being fixed directly on to the surface or it can be inset into the inner leaf of a cavity wall Be...

Страница 7: ...flue connection on the back of the heat exchanger Note that the two flue tubes are not concentric and that the inner tube is positioned towards the top of the outer tube Using a 3 5mm diameter drill...

Страница 8: ...inner holes as shown in Figure 4 4 Temporally screw the convector box to the inner wall plate with four M5 screws Place the convector box over the protruding flue pipe and push the box into the hole...

Страница 9: ...ox flange Fix the heat exchanger through the convector box flanges to the inner fascia using the M5 bolts supplied Replace the self tapping screws that secure the flue to the wall plate Seal the flue...

Страница 10: ...panel slides up and down freely and locks in the top position COMMISSIONING 1 Before attempting to light the appliance the gas supply must be turned on by removing the cap from the isolator fitting a...

Страница 11: ...s from your fire we recommend that it be serviced annually 7 These instructions are provided to assist you to operate the fire correctly and should be kept in a safe place 8 If you have any reason to...

Страница 12: ...ger period d Depress control knob A slightly and turn anti clockwise to the ON position The main burner will not operate until this is done The main burner may light depending on the position of Contr...

Страница 13: ...the DOWN button on the handset Release when the flame is at the desired height or has gone out Once again the electric motor should be heard moving Control Knob B Cleaning the fire Ensure that the app...

Страница 14: ...wed of not smoking eating or drinking in the work area and that hands are washed before eating or drinking The appliance should be serviced at least once a year by a registered engineer and must inclu...

Страница 15: ...After cleaning the glass door inside and out replace it and secure with the eight nuts Tighten the nuts evenly Stubborn marks can be removed with steel wool and detergent AFTER REFITTING THE APPLIANCE...

Страница 16: ...he event of a part requiring replacement the parts list is as follows Part Description Part Number Motorised valve CV 104103 Remote hand control Receiver CV 104413 Pilot Burner NG Model CV 104506 Inje...

Страница 17: ...17 B 124830 Issue 2 BFM Europe Limited Trentham Lakes Stoke on Trent Staffordshire ST4 4TJ Tel 01782 339000 Fax 01782 339009 Email info bfm europe com www bfm europe com...

Отзывы: