background image

OWNER’S GUIDE

MODELS: 

EBHN500 
EBHN750
EBHN1000 
EBHN1250 
EBHN1500 
EBHN500-8 
EBHN750-8 
EBHN1000-8
EBHN1250-8
EBHN1500-8

TOOLS REQUIRED

Phillips Screwdriver

Straight Screwdriver

Wire Strippers

Drill or Hammer

Level

Punch or Chisel

Drill Bits

Utility Knife

(4) Wood Screws

(3) Wire Nuts

(1) Strain Relief Connector

IMPORTANT INSTRUCTIONS

SAVE THESE INSTRUCTIONS

WARNING!

Turn the electrical power off at the electrical panel
board (circuit breaker or fuse box) and lock or tag the
panel board door to prevent someone from turning
on power while you are working on the heater.
Failure to do so could result in serious electrical
shock, burns, or possible death.  

When using electrical appliances, basic precautions should
always be followed to reduce the risk of fire, electric shock, and
injury to persons, including the following:
1. Read all instructions and labels before installing this heater. 

2.

WARNING

A heater has hot and arcing parts inside. Do not install in
areas where gasoline, paint or flammable liquids are stored or
excessive lint or dust are present.

3.

WARNING

This heater is hot when in use. To avoid burns, do not let bare skin
touch hot surfaces. Keep combustible materials, such as furniture,
pillows, bedding, papers, clothes and curtains away from heater.

4. To prevent possible fire, do not block air intakes or exhaust in

any manner. Do not use on soft surfaces, like a bed, where
openings may become blocked. Heaters must be kept clean of
excessive lint, dirt and debris. (See Maintenance Instructions).

5.

Risk of electrical shock

. Do not insert or allow foreign objects to

enter any ventilation or exhaust opening as this may cause an
electric shock or fire, or damage the heater.

6. Do not place heater below an electrical convenience receptacle.

7.

WARNING

Overheating or fire may occur

. Do not install the heater behind

doors. 

8. Use extreme caution when any heater is used near children or

invalids and whenever the heater is left operating unattended.

9.

WARNING

Do not operate after heater malfunctions or has been dropped
or damaged in any manner.

10.

WARNING

Risk of fire. Do not block heater

minimum of 12 inches in front

and above, 6 inches on both sides.  

11.Use this heater only as described in this manual. Any other use

not recommended by the manufacturer may cause fire, electrical
shock, or injury to persons.

12.

Verify that the electrical supply wires are the same voltage as
the heater.

The heater must be grounded to the grounding

screw provided. If you need to install a new circuit or need
additional wiring information, consult a qualified electrician.

Tel: 360-693-2505  www.cadetco.com  P.O. Box 1675  Vancouver, WA  98668-1675

Features & Benefits

Whisper quiet operation and low surface temperatures

Filled with non-toxic, non-hazardous thermal fluid

Self-contained hermetically sealed element design requires no
plumbing, piping, or other water supply

Thermal fluid capacity offers better heat retention, which creates
less cycling and keeps more consistent room temperatures

Designed to reduce the effects of indoor allergens

7-year element warranty

Summary of Contents for Softheat EBHN500

Page 1: ...ept clean of excessive lint dirt and debris See Maintenance Instructions 5 Risk of electrical shock Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause...

Page 2: ...l drastically reduce the heater s output Hooking a 120 volt heater to a 240 volt power supply will destroy the heater LEVEL The Softheat baseboard heater must be properly leveled when installed in ord...

Page 3: ...be planned and run before heating units are set in place Standard units are wired from left end of the heater only See Figure 5 for internal heater wiring When wiring unit through rear remove knock o...

Page 4: ...temperature before continuing 3 Remove front panel 4 Vacuum inside the unit being careful not to damage the aluminum fins on the heater tube How To Operate Your Heater WARNING The heater must be inst...

Page 5: ...obligation or liability in connection with its products other than as set out herein If you believe your Cadet product is defective please contact Cadet Manufacturing Co at 360 693 2505 during the war...

Page 6: ...in pelusas suciedad ni residuos excesivos Consulte las instrucciones de mantenimiento 5 Riesgo de electrocuci n No introduzca ni permita que ingresen objetos en las aberturas de la ventilaci n o escap...

Page 7: ...ltios a un suministro de energ a de 240 voltios se destruir el calentador NIVEL El calentador de z calo Softheat debe estar correctamente nivelado cuando se instale para que la c mara de calentamiento...

Page 8: ...igura 2 4 Retire el destapadero ranurado m s cercano a los cables de suministro e instale un conector con alivio de tensi n 5 Tire los alambres el ctricos por el conector y f jelos dejando que sobresa...

Page 9: ...EAT HIDR NICOS PASO 3 Termostato Para obtener mejores resultados use un termostato mural electr nico Cadet o un juego de termostato DPST de tapa extrema EBKN Se recomienda contar con un termostato par...

Page 10: ...arant a usted considera que su producto Cadet presenta defectos comun quese con Cadet Manufacturing Co llamando al 360 693 2505 para obtener instrucciones sobre c mo tramitar la reparaci n o el reempl...