If  plasterwork  requires  to  be  made  good,  please  pay  attention  to  note  no.  3  on 
page 2 of these instructions 

Inset Installation 

To inset the Limours gas fire, a wall plate, supplied separately, must be used. 

Select a position for the appliance and the height required from the centre of the 
glass  panel  to  the  floor.  Cut  a  hole  in  the  inner  leaf  of  the  cavity  wall  to  the 
dimensions shown in Figure 5. A lintel may be required to support the masonry 
over the opening .Any cavity wall insulation should be held back away from the 
appliance.    Drill a  152mm  diameter  hole  in  the  outer  leaf  of  the  cavity  wall  for 
the flue 157mm above the position of the centre of the glass panel. Ensure that 
the centre of the flue is at least 700mm above finished floor level. 

 

 

 

 

 

 

 

 

 

 

 

Thread the outside wall plate onto the flue and push the flue into the wall from 
the  outside.  Apply  mastic  to  the  rear  face  of  the  wall  plate  and  fix  to  the  wall 
using  screws  and  wall  plugs.  Make  sure  the  plate  is  fixed  the  correct  way  up. 
(See Figure 3) Slide the flue further into the wall until the tabs on the wall plate 
line up with the holes in the outer flue tube. Temporally fix the tube to the wall 
plate  with  the  self  tapping  screws  provided.  Use  the  inner  holes  as  shown  in 
Figure 4. 

Temporally screw the convector box to the inner wall plate with four M5 screws. 
Place the convector box over the protruding flue pipe and push the box into the 
hole  already  cut  in  the  inner  leaf  of  the  cavity  wall.  Centre  the  convector  box 
over the flue pipe. Once level, fix the inner wall plate to the wall with six screws 
and wall plugs. Cover the access holes to these screws with the six black plastic 
plugs  supplied.  Once  the  convector  box  has  been  finally  secured  to  the  inner 
fascia  the  arrangement  can  be  considered  to  have  sealed  the  cavity.  Any  gaps 
around the inner fascia and any other gaps can be sealed with mastic. 

From the inside of the convector box measure along the flue 6mm. At this point 
draw  a  line  completely  around  the  outer  pipe.  Unscrew  the  self  tapping  screws 
securing  the  outer  flue  tube  to  the  wall  plate  and  withdraw  the  flue  assembly. 
Move  the  polystyrene  support  ring  inside  the  flue  assembly  to  a  position  near 
the marked line. Cut the excess flue of at the marked line. De-bur the cut edges 
and remove the polystyrene ring.  

Slide  the  remaining  piece  of  flue,  which  should  include  the  terminal,  on  to  the 
flue connection on the back of the heat exchanger. Note that the two flue tubes 
are  not  concentric and that  the  inner  tube is  positioned towards the  top  of  the 
outer  tube.    Using  a  3.5mm  diameter  drill,  drill  holes  through  the  holes  in  the 

Figure 5 

Содержание KBFP00RN

Страница 1: ...Heater MODEL NUMBER KBFP00RN INSTALLATION USER AND SERVICING INSTRUCTIONS THESE INSTRUCTIONS MUST REMAIN WITH THE USER This appliance is suitable for use on Natural Gas G20 at a supply pressure of 20...

Страница 2: ...s is not a Do it yourself product and it must be installed by a competent person 2 The Installation Instructions must be adhered to without exception 3 The heat from this appliance will cause the wall...

Страница 3: ...a Panel b Decorative trim and 4 magnets if ordered Inset Installations only a Wall plate must be used for Inset Installations APPLIANCE DATA KBFP00RN GAS TYPE NATURAL GAS SUPPLY PRESSURE 20 mbar HEAT...

Страница 4: ...r the inset installation 3 Flue Terminal Position The minimum distances permissible from the flue terminal to obstructions and ventilation openings are shown below DIMENSION TERMINAL POSITION MINIMUM...

Страница 5: ...gh the whole base of the builders opening fireplace recess or beneath the flue box b Project at least 275mm in front of the glass window panel c Project at least 150mm beyond each side of the edge of...

Страница 6: ...s with the approval of the designers of the dwelling Fitting This appliance can be installed either by being fixed directly on to the surface or it can be inset into the inner leaf of a cavity wall Be...

Страница 7: ...flue connection on the back of the heat exchanger Note that the two flue tubes are not concentric and that the inner tube is positioned towards the top of the outer tube Using a 3 5mm diameter drill...

Страница 8: ...inner holes as shown in Figure 4 4 Temporally screw the convector box to the inner wall plate with four M5 screws Place the convector box over the protruding flue pipe and push the box into the hole...

Страница 9: ...ox flange Fix the heat exchanger through the convector box flanges to the inner fascia using the M5 bolts supplied Replace the self tapping screws that secure the flue to the wall plate Seal the flue...

Страница 10: ...panel slides up and down freely and locks in the top position COMMISSIONING 1 Before attempting to light the appliance the gas supply must be turned on by removing the cap from the isolator fitting a...

Страница 11: ...s from your fire we recommend that it be serviced annually 7 These instructions are provided to assist you to operate the fire correctly and should be kept in a safe place 8 If you have any reason to...

Страница 12: ...ger period d Depress control knob A slightly and turn anti clockwise to the ON position The main burner will not operate until this is done The main burner may light depending on the position of Contr...

Страница 13: ...the DOWN button on the handset Release when the flame is at the desired height or has gone out Once again the electric motor should be heard moving Control Knob B Cleaning the fire Ensure that the app...

Страница 14: ...wed of not smoking eating or drinking in the work area and that hands are washed before eating or drinking The appliance should be serviced at least once a year by a registered engineer and must inclu...

Страница 15: ...After cleaning the glass door inside and out replace it and secure with the eight nuts Tighten the nuts evenly Stubborn marks can be removed with steel wool and detergent AFTER REFITTING THE APPLIANCE...

Страница 16: ...he event of a part requiring replacement the parts list is as follows Part Description Part Number Motorised valve CV 104103 Remote hand control Receiver CV 104413 Pilot Burner NG Model CV 104506 Inje...

Страница 17: ...17 B 124830 Issue 2 BFM Europe Limited Trentham Lakes Stoke on Trent Staffordshire ST4 4TJ Tel 01782 339000 Fax 01782 339009 Email info bfm europe com www bfm europe com...

Отзывы: