Place  ten  ‘Cotswold  Stone’  pieces  from  the  second  packet  on  top  of  the  black 
ceramic granules in front of the front air guide as shown in Figure 6.  

Place  the  remaining  ten  ‘Cotswold  Stone’  pieces  from  the  second  packet across  
the air guides pushing each piece down on a location spike formed in the front 
air guide. See Figure 7 on previous page. 

It  is  important  that  decorative  ‘Cotswold  Stone’  pieces  are  placed  as  per  these 
instructions. 

Closing the Glass Door 

Place  the  glass  door  in  position  over  the  studs  on  the  heat  exchanger  making 
sure the joint in the rope seal lies along the lower edge. Secure in position with 
the eight nuts. Tighten evenly. 

Installing the Fascia Panel 

Check that the fascia panel is mounted the correct way up. A TEE is punched in 
the top of the inner flanges. 

Ensure the four M4 screws are mounted in their bushes on the inner flanges. 

3  

Offer  the  fascia  up  to  the  appliance  and  slide  the  heads  of  the  M4  screws 
through  the  cut  –  outs  and  into  the  slots  formed  in  the  sides  of  the  convector 
box. 

4

 

Make sure that the fascia panel slides up and down freely and locks in the top 

position.  

C

OMMISSIONING

Before  attempting  to  light  the  appliance  the  gas  supply  must  be  turned  on  by 
removing  the  cap  from  the  isolator  fitting  and  unscrewing  the  plug  all  the  way 
out. Replace the cap making sure that the tab engages with the slot in the top of 
the  plug.  Tighten  the  cap  securely.  Check  all  joints  with  leak  detection  fluid. 
Light the appliance in accordance with the instructions in the lighting section. 

2. 

a. 

Slide  back  the  battery  compartment  cover  and  insert  the  four  AA  size 

alkaline  batteries  observing  the  correct  polarities.  Replace  the  cover  and  place 
the battery box on the floor of the convector box.  

 

b. 

Fit the battery into the  handset by removing  the access cover  in the  rear 

of  the  handset  and  inserting  a  9  volt  PP3  size  battery.  Connect  the  battery  by 
pushing the  connector on to the  terminals. Make sure  the  battery  is connected 
correctly. Replace the access cover.  

Briefing the User 

1

 

Demonstrate the full operation of the appliance to the customer.  

2

 

Inform  the  customer  that  all  cleaning  procedures  should  be  carried  out  only 
when the appliance is cold. 

3

 

Leave these instructions with the customer. 

Advise  the  importance  of  having  the  appliance  serviced  on  an  annual  basis.

Содержание KBFP00RN

Страница 1: ...Heater MODEL NUMBER KBFP00RN INSTALLATION USER AND SERVICING INSTRUCTIONS THESE INSTRUCTIONS MUST REMAIN WITH THE USER This appliance is suitable for use on Natural Gas G20 at a supply pressure of 20...

Страница 2: ...s is not a Do it yourself product and it must be installed by a competent person 2 The Installation Instructions must be adhered to without exception 3 The heat from this appliance will cause the wall...

Страница 3: ...a Panel b Decorative trim and 4 magnets if ordered Inset Installations only a Wall plate must be used for Inset Installations APPLIANCE DATA KBFP00RN GAS TYPE NATURAL GAS SUPPLY PRESSURE 20 mbar HEAT...

Страница 4: ...r the inset installation 3 Flue Terminal Position The minimum distances permissible from the flue terminal to obstructions and ventilation openings are shown below DIMENSION TERMINAL POSITION MINIMUM...

Страница 5: ...gh the whole base of the builders opening fireplace recess or beneath the flue box b Project at least 275mm in front of the glass window panel c Project at least 150mm beyond each side of the edge of...

Страница 6: ...s with the approval of the designers of the dwelling Fitting This appliance can be installed either by being fixed directly on to the surface or it can be inset into the inner leaf of a cavity wall Be...

Страница 7: ...flue connection on the back of the heat exchanger Note that the two flue tubes are not concentric and that the inner tube is positioned towards the top of the outer tube Using a 3 5mm diameter drill...

Страница 8: ...inner holes as shown in Figure 4 4 Temporally screw the convector box to the inner wall plate with four M5 screws Place the convector box over the protruding flue pipe and push the box into the hole...

Страница 9: ...ox flange Fix the heat exchanger through the convector box flanges to the inner fascia using the M5 bolts supplied Replace the self tapping screws that secure the flue to the wall plate Seal the flue...

Страница 10: ...panel slides up and down freely and locks in the top position COMMISSIONING 1 Before attempting to light the appliance the gas supply must be turned on by removing the cap from the isolator fitting a...

Страница 11: ...s from your fire we recommend that it be serviced annually 7 These instructions are provided to assist you to operate the fire correctly and should be kept in a safe place 8 If you have any reason to...

Страница 12: ...ger period d Depress control knob A slightly and turn anti clockwise to the ON position The main burner will not operate until this is done The main burner may light depending on the position of Contr...

Страница 13: ...the DOWN button on the handset Release when the flame is at the desired height or has gone out Once again the electric motor should be heard moving Control Knob B Cleaning the fire Ensure that the app...

Страница 14: ...wed of not smoking eating or drinking in the work area and that hands are washed before eating or drinking The appliance should be serviced at least once a year by a registered engineer and must inclu...

Страница 15: ...After cleaning the glass door inside and out replace it and secure with the eight nuts Tighten the nuts evenly Stubborn marks can be removed with steel wool and detergent AFTER REFITTING THE APPLIANCE...

Страница 16: ...he event of a part requiring replacement the parts list is as follows Part Description Part Number Motorised valve CV 104103 Remote hand control Receiver CV 104413 Pilot Burner NG Model CV 104506 Inje...

Страница 17: ...17 B 124830 Issue 2 BFM Europe Limited Trentham Lakes Stoke on Trent Staffordshire ST4 4TJ Tel 01782 339000 Fax 01782 339009 Email info bfm europe com www bfm europe com...

Отзывы: