Chapter 6 List of Parameters
79
Function
code
Name
Descriptions
Unit
Factory
setting
Modif.
Setting
range
0: Disable
1: Save the segment frequency
when power off
: Time unit
selector for each step
0: Second
1: Minute
C2.01 Step 1 setting
:
0: Multiple frequency N
(Ncorresponding to current step)
1: Defined by A0.02
2: Multiple closed-loop reference N
(Ncorresponding to current step)
3: Defined by C1.01
:
0: Forward
1: Reverse
2: Defined by operation command
:
0: Acc/Dec time 1
1: Acc/Dec time 2
2: Acc/Dec time 3
3: Acc/Dec time 4
1
000
O 0 323H
C2.02 Step 1 operating time
0.0 6500.0
0.1
20.0
O 0 65000
C2.03 Step 2 setting
Same as C2.01
1
000
O 0 323H
C2.04 Step 2 operating time
0.0 6500.0
0.1
20.0
O 0 65000
C2.05 Step 3 setting
Same as C2.01
1
000
O 0 323H
C2.06 Step 3 operating time
0.0 6500.0
0.1
20.0
O 0 65000
C2.07 Step 4setting
Same as C2.01
1
000
O 0 323H
C2.08 Step 4 operating time
0.0 6500.0
0.1
20.0
O 0 65000
C2.09 Step 5 setting
Same as C2.01
1
000
O 0 323H
C2.10 Step 5 operating time
0.0 6500.0
0.1
20.0
O 0 65000
C2.11 Step 6 setting
Same as C2.01
1
000
O 0 323H
C2.12 Step 6 operating time
0.0 6500.0
0.1
20.0
O 0 65000
C2.13 Step 7 setting
Same as C2.01
1
000
O 0 323H
C2.14 Step 7 operating time
0.0 6500.0
0.1
20.0
O 0 65000
C2.15 Step 8 setting
Same as C2.01
1
000
O 0 323H
C2.16 Step 8 operating time
0.0 6500.0
0.1
20.0
O 0 65000
C2.17 Step 9 setting
Same as C2.01
1
000
O 0 323H
C2.18 Step 9 operating time
0.0 6500.0
0.1
20.0
O 0 65000
C2.19 Step 10 setting
Same as C2.01
1
000
O 0 323H
C2.20 Step 10 operating time
0.0 6500.0
0.1
20.0
O 0 65000
C2.21 Step 11 setting
Same as C2.01
1
000
O 0 323H
C2.22 Step 11 operating time
0.0 6500.0
0.1
20.0
O 0 65000
C2.23 Step 12 setting
Same as C2.01
1
000
O 0 323H