Chapter 6 List of Parameters
53
Chapter 6
List of Parameters
FV20
identified by
The parameter descriptions are listed in the tables below.
Table 6-1 Descriptions of Function Code Parameter Structure Table
No. Name
Description
1
Function code
The number of function code
2
Name
The name of function code
3
Setting range
The setting range of parameters.
4
Unit
The minimum unit of the setting value of parameters.
5
Factory setting
The setting value of parameters after the product is delivered
6
Modification
modified.
O
Denotes the parameters can be modified during operation or at STOP state;
Denotes the parameters cannot be modified during operating;
Denotes the parameters are actually detected and cannot be revised;
Denotes the parameters are defaulted by factory and cannot be modified ;
(When you try to modify some parameters, the system will check their modification property
automatically to avoid mis-modification.)
Note:
1 Parameter settings are expressed in decimal (DEC) and hexadecimal (HEX). If the parameter is expressed in
hexadecimal, the bits are independent to each other.The value of the bits can be 0 F.
2
the factory settings. But the actual detected or recorded parameters cannot be initialized;
It is defaulted that no parameters except A0.03 are allowed changing. If you need change them,please first
set b4.02(parameter write-in protection) from 1 to 0.
Table 6-2 List of Parameters
Function
code
Name
Descriptions
Unit
Factory
setting
Modif.
Setting
range
Group A0.Basic operating parameters
A0.00 User password
0: No password protection.
Others: Password protection.
1
0
O 0 FFFF
A0.01 Control mode
LED Unit s place: Motor 1 control mode
0: Vector c ontrol without PG
1: Vector control with PG
2: V/F control without PG
3: V/F control with PG
1
2
X 0 2