Chapter 4 Operation Instructions of Kinco VFD
49
Forward / Reverse indicator
ON: Local control LOC
OFF: Remote control REMOTE
ON: Reverse
OFF: Forward
ON: Local contro
Flashing: Self-learning status
OFF: Remote control
Chapter 4
Operation Instructions of Kinco VFD
4.1 Using Operation Panel
4.1.1
Operation panel is used to setup the drive and display parameters, it is LED display. As shown in Fig.4-1
Function indicator:
RUN/TUNE: When the light is on, it indicates that the inverter is in running state. When the light is flashing, it
indicates that the inverter is in the self-learning state. When the light is off, the inverter is in the
stop state.
LOC/REMOTE: Panel operation, terminal operation and communication control indicator.
LOCAL/REMOT Light off
Run/Stop in panel control
LOCAL/REMOT Light on
Run/Stop in terminal control
LOCAL/REMOT Light blink Run/Stop in communication control
ON: Current limit
OFF: No limit
ON: Fault alarm
OFF: Normal
RUN key
SHIFT key
ENTER key
Multi-function key
STOP / RESET key
Forward / Reverse
Potentiometer
Unit indicator
Current limit indicator
Running indicator
Command source indicator
MENU key
Add / Sub key
Fault indicator